AUTO-GREASING
NOTICE
The auto-greasing system is used only for all connected lubrication points. The other lubrication points
have to be greased manually.
Changing the lubrication interval times
The auto-greasing system is adjusted for the normal use.
The settings when shipping from the factory are as follows.
Lubrication interval: Every 1 hour
Lubrication time: 9 minutes
When changing the settings of the lubrication cycle for the heavy-duty operations, consult your Komatsu distrib-
utor.
Method for operating the auto-greasing system
The pump with grease tank is located at the position as shown
in the figure.
For details, see “CHECKING AUTO-GREASING AND OPERA-
TION METHOD FOR FILLING GREASE (6-23)”.
Turn the starting switch to ON position (B).
The power supply to the grease pump is turned on.
The auto-greasing pilot lamp is lit for 2 seconds.
Display and control unit
The display and control unit are protected by a transparent
plastic cover against sprayed water and mechanical damages.
For setting, the cover needs to be removed and remounted af-
terwards.