AKD-C Installation | 9 Electrical Installation
9.9 Drive String Connection
AKD-C support two strings to connect up to 16 AKD-N drives.
Use IP67 grommets for leading the hybrid cable out of the cabinet.
For connecting the first AKD-N to one of the DC
strings the Kollmorgen cable type CCNCN1 must
be used. This cable is a Y type adapter with one
hybrid connector on the AKD-N end and two con-
nectors on the AKD-C end with separate DC power
and local fieldbus lines.
To ensure protection class IP67, Kollmorgen recom-
mends cable entry system KDL/S combined with
cable entry grommet KDT/S manufactured by :
Murrplastik Systemtechnik GmbH
Fabrikstraße 10
71570 Oppenweiler, Germany
Phone: +49 (0)7191 482-0
Website:
E-Mail:
Solution for rotary tables
If AKD-N must be mounted on a rotary table, it is
necessary to use slip ring assemblies for energy
and data transfer between AKD-C in the cabinet
and AKD-N on the rotary table.
Kollmorgen cooperates with company
STEMMANN-TECHNIK for user specific slip ring
assembly solutions.
Please contact:
STEMMANN-TECHNIK GmbH
Niedersachsenstraße 2
48465 Schüttorf, Germany
Phone: +49 (0)592381-0
Website:
E-Mail:
The Safety Function STO has been tested with
STEMMANN slip rings 6263576 and 6263577.
These slip rings can be used as stand-alone mod-
ules or in a slip ring cassette.