background image

4.5

Starting the generating set

Once the daily checks have been performed, and having read the instructions and safety regulations carefully: 

If the outdoor temperature is above 0°C:

If the outdoor temperature is below 0°C:

1.

Open the fuel tap (A5).

1. Open the fuel tap (A5)

2.

Check that the air filter is in the normal position for use 
(D1).

2. Place the air filter in the "low temperature" position (D2).

3.

If  the  generating  set  is  cold,  move  the  choke  control 
(A8) to position "

I

".

3. Move the choke control (A8) to position "

I

".

4.

Move the switch (A7) to "

ON

ON

"

" or "

I

I

".

".

4. Move the switch (A7) to "

ON

ON

"

" or "

I

I

".

".

5.

Slowly pull the starter-recoil reel handle (A9) until there 
is some resistance, then let it return gently.

5. Slowly  pull  the  starter-recoil  reel  handle  (A9)  until  there  is  some 

resistance, then let it return gently.

6.

Then  pull  the  starter-recoil  reel  handle  quickly  and 
sharply until the unit starts.

6. Then pull the starter-recoil reel handle quickly and sharply until the 

unit starts.

If the unit does not start, wait one minute before repeating the 
process no more than three times.

If the unit does not start, wait one minute before repeating the process no 
more than three times.

4.6

Using the electricity supplied

1.

Allow the unit speed to stabilise and the temperature to rise (approx. 3 to 5 min.).

2.

If the choke (A8) was used, return it gradually to its original position.

3.

Connect the equipment to be used to the electrical sockets (A11) on the unit.

4.

Place the voltage selector (A10) in the position corresponding to the voltage you need to use (115V or 230V).

4.7

Switching the generating set off

1.

Disconnect the equipment used, taking care to close the cover for the unit's electrical sockets (A11) .

2.

Allow the unit to run idle for 1 or 2 minutes.

3.

Set the switch (A7) to "

OFF

" or "

": the unit will shut down.

4.

Close the fuel taps (A5).

5.

Ensure the unit is properly ventilated and to avoid any risk of fire, wait for it to be fully cool (at least 30 minutes) before 

covering it and storing it.

Even when the unit is turned off, the engine continues to give off heat

.

5 Generating set maintenance

As  a  safety  measure,  maintenance  should  be  performed  on  the  generating  set  regularly  and  carefully  by  people  who  have  the 
necessary  experience  and  are  equipped  with  suitable  tools,  in  respect  of  current  regulations.  The  maintenance  operations  to  be 
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with 
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the 
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set 
maintenance has not be performed correctly.

5.1

Reminder of use

Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. 

The oil, filter elements and, 

where  present,  the  spark  plug,  are  consumables  which  must  be  in  good  condition  for  the  unit  to  operate  correctly. 
Replace  them  regularly  as  often  as  is  needed  (the  reference  for  ready-to-use  maintenance  kits  is  given  in  the  table  of 
technical  specifications  where  applicable). 

The  warranty  becomes  void  in  the  event  of  failure  to  respect  the  maintenance 

recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.

5.2

Maintenance intervals table

The  maintenance  frequency  is  given  as  an  indication  only  and  is  for  devices  using  fuel  and  oil  complying  with  the  specifications 
given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements. 
Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached. 

The 

warranty will be invalidated if maintenance of the unit has not been performed correctly.

After

In hours, months or years, whichever comes first

Operation to be carried out:

5 hours

3 months/

50 hours

Every

3 months/

50 hours

Every

6 months/
100 hours

Every

1 year/

200 hours

Every

2 years/

500 hours

Clean the unit

X

X

Clean the spark arrester

X

Unit

Replace the spark plug

X

Oil

Change

X

X

X

Replace the fuel filter

X

Fuel

Clean the sediment bowl

X

Clean

X

X

X

X

Air filter

Replace

X

Part numbers of parts to be used during maintenance:

RKS1

Major service 

to be carried 

out by one of 

our agents. 

France: 

0.806.800.107  

(call charge)

Major service 

to be carried 

out by one of 

our agents. 

France: 

0.806.800.107  

(call charge)

5.3

Performing the maintenance operations

1.

Shut down the unit and wait at least 30 minutes for it to cool.

2.

Disconnect the cap(s) of the spark plug(s) and disconnect the "-" terminal on the battery (if fitted).

3.

Carry out maintenance in accordance with the information given in this manual and, to avoid the risk of damage to the unit, 
only use original parts or their equivalent.

17/22

Summary of Contents for SDMO PERFORM 3000 XL TB UK C5

Page 1: ...33522201001_1_1 11 2019 Manuel d utilisation et d entretien Notice originale Instruction and maintenance manual Translation of the original note PERFORM 3000 XL TB UK C5 3000 XL TB UK C5 ...

Page 2: ...A 16 11 17 9 4 3 2 12 1 6 8 5 10 5 7 14 15 11 13 18 ...

Page 3: ...B C 3 2 1 5 3 5 4 4 6 7 8 1 2 ...

Page 4: ...D E F FRANCE 0 806 800 107 Prix appel 1 2 3 6 4 5 1 3 2 1 2 ...

Page 5: ...material damage 2 Instructions and safety regulations personal protection The instructions and safety regulations must be read carefully and followed to avoid endangering personal health and safety If there is any doubt over the meaning of the instructions please contact your nearest agent 2 1 Meaning of the pictograms on the generating set DANGER DANGER risk of electric shock GROUND DANGER risk o...

Page 6: ...orary installation work site show fairground etc A If the unit is not equipped with an integrated differential protection device at delivery standard version with insulated neutral on the unit s earth terminal Use a differential device calibrated to 30mA at the output of each of the unit s sockets place each device at least 1 metre from the unit protecting it from weather conditions If one or more...

Page 7: ...aces of fuel with a clean cloth and wait until the vapors have dispersed before starting the unit If the fuel is exposed to high temperatures for a period of several hours containers or generating set stored in a vehicle parked in the sun for example harmful vapors could be released causing a risk of poisoning or of feeling unwell The fluids used by the units such as oils and fuels are dangerous p...

Page 8: ...n well ventilated and sheltered from bad weather 2 Position the unit on a flat horizontal surface that has sufficient load bearing capacity to prevent it from sinking The units are designed for stationary operation they must not be installed on a vehicle or other mobile equipment unless a study taking into account the different specific requirements for use of the unit has been carried out 3 Check...

Page 9: ...he maintenance table The interval for this is supplied as a guide and for generating sets operating with fuel and oil which conform to the specifications given in this manual The maintenance intervals can be shortened depending on the generating set s operating conditions and requirements It is important to note that the warranty shall not be valid if generating set maintenance has not be performe...

Page 10: ... 2 Remove the filter elements D5 D6 for cleaning 3 Clean the foam element wash it in soapy water carefully rinse it and leave it to dry completely 4 Soak the foam element in a little clean engine oil and squeeze it to remove any excess oil do not wring it out If there is too much oil remaining in the foam the unit will emit smoke when it is first started 5 Replace the paper element 6 Refit the fil...

Page 11: ...e cylinder and valves 6 Remove the spark plug A16 F2 then via its aperture pour in approx one teaspoon of new engine oil 7 Refit a new spark plug in its place 8 Pull the starter recoil reel handle A9 several times to distribute the oil inside the cylinder Storing the unit 9 Clean the unit 10 Cover it with a protective cover and store it in its normal position in a clean dry and well ventilated are...

Page 12: ...uired power must not exceed the unit s maximum power 8 3 Generating set identification The identification plate for the unit example shown below is affixed inside one of the skirts or on the chassis A Model B CE EAC marking C Guaranteed acoustic power level D Maximum power E Nominal power F Power factor G Ground H Current amperage I Current frequency J Current voltage K Protection rating L Referen...

Page 13: ...dent SDMO Industries 9 Conditions of warranty COMMERCIAL WARRANTY Your unit is covered by a commercial warranty granted by SDMO Industries This warranty must be applied by the distributor from which you purchased your unit in accordance with the following provisions TERM The warranty for your unit is valid for a period or 36 months or 2000 operating hours from the date of purchase It applies to wh...

Page 14: ... to used items The statutory guarantee applies independently of the commercial warranty provided by SDMO Industries You may also decide to implement the guarantee applicable to hidden defects with your unit under the conditions set out in article 1641 of the Civil Code If there is a hidden defect with your unit and you are required to provide proof you may choose between cancellation of the sale o...

Reviews: