7.1
Generator Smart Care (Option)
If the unit has been equipped with the "GS101-Generator Smart Care" option (A18),
it is necessary to change the batteries in the Bluetooth GSC101 box when the
warning is displayed in the Generator Smart Care application (approximately every
two years).
1.
Use a small crosshead screwdriver to open the cover of the box,
2.
Remove the used batteries and take them to a waste collection point so
that they can be recycled,
3.
Fit two new AAA batteries, observing the polarity (+/-),
4.
Close the unit cover and carefully tighten the screws.
8 Technical specifications
8.1
Operating conditions
The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
8.2
Capacity of the generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*
This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher
load when starting. This minimum required power must not exceed the unit's maximum power
.
8.3
Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
power level
(D):
Maximum power
(E):
Nominal power
(F):
Power factor
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M): Serial number
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
Engine manufacturer:
(e.g.
Kohler)
Engine serial number:
(e.g Kohler (SERIAL
NO. 4001200908))
……/………….. - ……..………..….…. - ………
……..……..………..….…..….
……..………..….….……..………..….….
8.4
Specifications
Model
PERFORM 3000 XL TB UK C5
Maximum power
2800 W
Rated output
2400 W
Acoustic pressure at 1 m
81 dB(A)
Acoustic measurement uncertainty
0,47 dB(A)
Engine type
CH270_C5
Maintenance kit
RKS1
Fuel tank capacity
13 L
Recommended fuel
Unleaded petrol
Recommended oil
10W30
Oil sump capacity
0,60 L
Oil cut-out*
O
Direct current
X
Alternating current
230V-10.4A
Circuit breaker(s)**
O
Socket type
2x2P+T -115V-16A + 1x2P+T-230V-16A
Spark plug type
330830012
Battery
x
Dimensions l x w x h
65 x 51 x 54 cm
Weight (without fuel)
47,5 kg
o: standard
x: not available
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the