background image

6 Transporting and storing the generating set

6.1

Transport and handling conditions

The unit should be handled gently and sudden movements should be avoided. Ensure that  the place where it is to be stored or 
used  is  carefully  prepared  beforehand.  Before  any  fixed  installation  on  a  trailer  or  inside  a  vehicle,  consult  one  of  our  approved 
agents.
Before transporting the unit, take the following necessary precautions:

1.

Check that the routes to be used are smooth and drivable. If it proves necessary to use uneven roads, drain the fuel into a 
container before setting off.

2.

Check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the battery (if fitted). 

3.

The unit should always be transported in its normal operating position; never lay it on its side. Ensure that the unit cannot 
fall from the vehicle carrying it, but without exerting too much force (risk of damaging the unit).

6.2

Storage conditions

This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For 
longer  periods  of  storage,  it  is  recommended  to  contact  your  nearest  agent  or  to  start  up  the  unit  for  a  few  hours  every  year, 
ensuring that the storage procedure is respected afterwards.

Drain the fuel and change the engine oil:

1.

Start the unit and allow it to operate until it runs out of fuel.

2.

Set the switch to OFF (A7).

3.

Clean the sediment bowl.

4.

Close the fuel taps (A5).

5.

Top up the oil.

Grease

 

the cylinder and valves:

6.

Remove the spark plug (A16-F2) then, via its aperture, pour in approx. one teaspoon of new engine oil.

7.

Refit a new spark plug in its place.

8.

Pull the starter-recoil reel handle (A9) several times to distribute the oil inside the cylinder.

Storing the unit:

9.

Clean the unit.

10. Cover it with a protective cover and store it in its normal position, in a clean, dry and well ventilated area.

7 Repairing minor faults

The unit…

Check that:

Solutions to be applied:

Does not start

The checks before starting have been 

performed.

NO

Perform the necessary checks.

YES

The start-up procedure has been 

followed correctly.

NO

Re-read the start-up procedure and repeat 

the start-up attempt.

YES

The equipment to be used has not 

been connected prior to starting.

NO

Disconnect the equipment then try to start 

the unit again.

YES

The spark plug is in good condition and 

correctly connected.

NO

Replace the spark plug (330830012).

YES

Stops

The oil level is correct.

NO

Top up with oil

.

YES

The fuel level is correct.

NO

Fill up with fuel

.

YES

The air filter is in good condition.

NO

Clean the air filter.

YES

Does not function normally 

(noise, smoke, etc.)

Maintenance has been correctly 

performed on the unit components.

NO

Perform maintenance on the unit as per 

the recommendations.

YES

Have the unit checked by one of our 

agents*.

Does not supply electrical 

current

The circuit breaker(s) has/have been 

tripped.

NO

Check the capacity of the unit and press 

the circuit breakers.

YES

The connected equipment and their 

power cords are not faulty.

NO

Try with another item of equipment and 

another power cord.

YES

Have the unit checked by one of our 

agents*.

*France: 0.806.800.107 (call charge).

19/22

Summary of Contents for SDMO PERFORM 3000 XL TB UK C5

Page 1: ...33522201001_1_1 11 2019 Manuel d utilisation et d entretien Notice originale Instruction and maintenance manual Translation of the original note PERFORM 3000 XL TB UK C5 3000 XL TB UK C5 ...

Page 2: ...A 16 11 17 9 4 3 2 12 1 6 8 5 10 5 7 14 15 11 13 18 ...

Page 3: ...B C 3 2 1 5 3 5 4 4 6 7 8 1 2 ...

Page 4: ...D E F FRANCE 0 806 800 107 Prix appel 1 2 3 6 4 5 1 3 2 1 2 ...

Page 5: ...material damage 2 Instructions and safety regulations personal protection The instructions and safety regulations must be read carefully and followed to avoid endangering personal health and safety If there is any doubt over the meaning of the instructions please contact your nearest agent 2 1 Meaning of the pictograms on the generating set DANGER DANGER risk of electric shock GROUND DANGER risk o...

Page 6: ...orary installation work site show fairground etc A If the unit is not equipped with an integrated differential protection device at delivery standard version with insulated neutral on the unit s earth terminal Use a differential device calibrated to 30mA at the output of each of the unit s sockets place each device at least 1 metre from the unit protecting it from weather conditions If one or more...

Page 7: ...aces of fuel with a clean cloth and wait until the vapors have dispersed before starting the unit If the fuel is exposed to high temperatures for a period of several hours containers or generating set stored in a vehicle parked in the sun for example harmful vapors could be released causing a risk of poisoning or of feeling unwell The fluids used by the units such as oils and fuels are dangerous p...

Page 8: ...n well ventilated and sheltered from bad weather 2 Position the unit on a flat horizontal surface that has sufficient load bearing capacity to prevent it from sinking The units are designed for stationary operation they must not be installed on a vehicle or other mobile equipment unless a study taking into account the different specific requirements for use of the unit has been carried out 3 Check...

Page 9: ...he maintenance table The interval for this is supplied as a guide and for generating sets operating with fuel and oil which conform to the specifications given in this manual The maintenance intervals can be shortened depending on the generating set s operating conditions and requirements It is important to note that the warranty shall not be valid if generating set maintenance has not be performe...

Page 10: ... 2 Remove the filter elements D5 D6 for cleaning 3 Clean the foam element wash it in soapy water carefully rinse it and leave it to dry completely 4 Soak the foam element in a little clean engine oil and squeeze it to remove any excess oil do not wring it out If there is too much oil remaining in the foam the unit will emit smoke when it is first started 5 Replace the paper element 6 Refit the fil...

Page 11: ...e cylinder and valves 6 Remove the spark plug A16 F2 then via its aperture pour in approx one teaspoon of new engine oil 7 Refit a new spark plug in its place 8 Pull the starter recoil reel handle A9 several times to distribute the oil inside the cylinder Storing the unit 9 Clean the unit 10 Cover it with a protective cover and store it in its normal position in a clean dry and well ventilated are...

Page 12: ...uired power must not exceed the unit s maximum power 8 3 Generating set identification The identification plate for the unit example shown below is affixed inside one of the skirts or on the chassis A Model B CE EAC marking C Guaranteed acoustic power level D Maximum power E Nominal power F Power factor G Ground H Current amperage I Current frequency J Current voltage K Protection rating L Referen...

Page 13: ...dent SDMO Industries 9 Conditions of warranty COMMERCIAL WARRANTY Your unit is covered by a commercial warranty granted by SDMO Industries This warranty must be applied by the distributor from which you purchased your unit in accordance with the following provisions TERM The warranty for your unit is valid for a period or 36 months or 2000 operating hours from the date of purchase It applies to wh...

Page 14: ... to used items The statutory guarantee applies independently of the commercial warranty provided by SDMO Industries You may also decide to implement the guarantee applicable to hidden defects with your unit under the conditions set out in article 1641 of the Civil Code If there is a hidden defect with your unit and you are required to provide proof you may choose between cancellation of the sale o...

Reviews: