23
1306246-W2-D
1.
Remove the male connector from the relay PCB (CN13).
2.
Connect the two or three wires from transformer and refit to the PCB.
Transformer
From Transformer
TERMINAL BLOCK
N
L
Transformer
Pump
To Mains
Brown
Brown
Black
Black
Red
Brown
CN13
RELA
Y PCBA
Black
Red
Red
Connect to Wired Pump
Relay PCB (CN13)
CN13
CN13
Brown
Black
Red
Advance Relay Board Showing Hardwired Connection to the Transformer
Configuration 1
Configuration 2
From Transformer
TERMINAL BLOCK
N
L
Brown
CN13
White
3 wires signal cable connection to relay
board
2 wires signal cable connection to relay
board
Caution!
Take care not to damage the relay board when making connections.
Important!
Make sure that you hold the
connector when you tighten the screws.
Summary of Contents for Mira Advance 8.7
Page 38: ...38 1306246 W2 D Notes ...
Page 39: ...39 1306246 W2 D Notes ...