35
1306246-W2-D
Tradesperson Maintenance - Inlet Filter Cleaning/Replacing
Read the section
'Important Safety Information'
first.
Electrical and water supplies to appliance
are turned off.
Remove cover screw, cover and splash
guard. Disconnect ribbon cable from
cover
Hold a spanner or other suitable grips
across flats of the metal connector.
Unscrew filter using another spanner
as shown. Clean or replace filter as
necessary. Refit filter making sure it is
screwed fully home.
Do not overtighten
.
Make sure all plumbing connections are
sealed before restoring water supply.
Re-
prime appliance
(refer to
'Installation'
)
before restoring electricity supply. Refit
splash guard, ribbon cable and cover.