30
1306246-W2-D
1. Have you primed the flow valve?
(See priming the shower) Failure to purge the air sufficiently from the flow valve
could lead to pulsating water flow.
2. Is the water supply pressure sufficient?
This shower is designed to be fitted to the mains water supply only. See
specifications for minimum pressure information.
3. Is the shower being connected to a waste pump?
The Advance Flex Extra (J09N) is designed to be wireless connected via Bluetooth
to the Whale Bluetooth transformer or hardwired to other transformers (Refer to
both Mira and Whale Bluetooth Set Up and Hardwired connection information)
Note!
Faults with loss of communication or pairing can be due to installation
issues, if a Bluetooth signal cannot be established the pump and shower should
be hardwired.
Installer Checklist