22
1306246-W2-D
1 2 3 4 5 6 7
10 30 60
1 2
1
2
3
4
5
6
7
8
BEAB CARE MODE
ON
OFF
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
Do not
remove label
1 2 3 4 5 6 7
10 30 60
1 2
Flex Extra J09N
Mira Advance Flex Extra (J09N) for use with the Instantmatch by
Whale® Digital Pump
Whale Instant Match Transformer
SDS236T (755.678), SDS233T (755.617)
SDS135T (755.649)
Jumper Settings and Cable Connection
1
2
3
4
5
6
7
8
BEAB CARE MODE
OFF
ON
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
Hardwired Connection
WIRED PUMP MODE
set to
ON
or
OFF
depending which wired
transformer used, see transformer
table.
If you are exchanging this Advance for a previous model (J97) that is using a pump
driver board.
1.
Remove and discard the driver board and its ribbon cable connections.
2.
Cut the connector block off the end of the 2 wires coming into the shower from
the waste pump.
3.
Connect the two wires to the small terminal block on the relay PCB (as shown).
For new hard wired installations many waste pump manufacturers supply the cable
to connect from the shower to the waste pump. If the cable is not supplied then Mira
can supply a 4m length cable (part number 1759.125) This should be installed and
connected as detailed.
Brown Black
Red
Summary of Contents for Mira Advance 8.7