Chapter 4 CVS-841/851
Installation
4.7.3 Connections of the transducers
Depending on the transducer type, the connections are different. Refer to the connecting diagram
below. Also note for the connections. If the Transducer Junction Box is used, connect each lead to a
designated terminal, and if the junction box is not used, solder two leads with PVC tape wound
appropriately for good isolation.
4.7.3.1 About TD cable
Except the TD-2001D (Single frequency, 200 kHz, 1 kW), all TD cables are PVC sheathed and has two
core wires (black and white) covered with shielding copper braid.
The TD-2001D is PVC sheathed and has four core wires (red, white, green, black) covered with
shielding copper braid.
4.7.3.2 Connecting the TD cable
[Single frequency TD except TD-2001D]
Connect the TD units to the Display unit as per the following diagram. Solder the cables and apply
winds of PVC tape to make sure of good isolation between the cables.
[Single frequency TD, TD-2001D]
The TX/RX section and the transducer cables are connected as follows:
CW-836-3M
To J7/Display rear panel
Red
Green
White
TD
(High Freq)
TD-2001D
Shield
CW-836-3M
To J7/Display rear panel
White
Black
Red
Green
Black
TD
(Low Freq)
Shield
White
Black
Red
Green
Black
White
Black
White
TD
(High Freq)
White
Black
TD
(Low Freq)
Shield
Shield
4-8
93132682-03