Chapter 5 Installation
CVS-126
5-10
0093132702-08
Connection with Speed Sensor or Water Temperature Sensor (Option)
When installing the optional speed sensor or water temperature sensor, connect to the [TD] connector
together with the transducer via the transducer cable (Type: CW-840-0.3M). For wiring, see the figure
below.
After soldering, implement the waterproof and insulation treatment on the connected part with the
self-melting tape.
Structure of Transducer Cable
Caution: Wind the insulation tape around the un-used lead wire for core-wires not to contact
each other.
Connection Table of Transducer
Transducer Cable
Transducer
No. of 2 core shield
Color of 2 core shield
TD-500T-2B
TD-500T-3B
3 Orange
Red
4 Shield
Shield
5 White
White
Connection Table of Speed Sensor and Water Temperature Sensor
Transducer Cable
Water Temperature Sensor / Speed Sensor
No. of lead
wire
Color of lead
wire
T-81 ST-80
ST-80-1
ST-90
ST-90-1
ST-100
ST-100-1
1 Blue
—
Green
Green
Green
2 Violet
—
Red
Red
Red
6 Green
Gray
White
White
White
7 Red
Gray
Brown
Brown
Brown
8 Black
—
Shield
Shield
Shield
Caution: No.8, SPD.GND (Black), only use for speed sensor.
Do not connect with other grounding wire.
2 core shield wire
TD1 (Orange)
TD2 (White)
Shield
SPD.PULSE (Blue)
SPD.VCC (Violet)
SPD.GND (Black)
TEMP.VCC (Green)
TEMP.SIG (Red)
lead wire
To the speed sensor
To the water temperature sensor
To transducer