ProLine P16800
43
12.14 Ambient Conditions
Operating environment
Use in enclosed, non-forced-ventilated areas on rolling
stock
Installation site according to EN 50155
Closed control cabinet,
Appendix C: 1 and 2
Pollution degree
PD 2
Height class according to EN 50125
AX, reduced isolation data for altitudes of
2000 to 4000 m above MSL
Temperature class according to EN 50125
TX
Operating temperature class according to EN 50155
OT4
Increased operating temperature class during switch-on
according to EN 50155
ST1, ST2
Temperature change class for rapid temperature changes
according to EN 50155
H1
Ambient temperature range: Operation
-40
…
70 °C (-40
…
158 °F)
short-time 85 °C (185 °F)
Ambient temperature range: Storage and transport
-40
…
90 °C (-40
…
194 °F)
Temperature at enclosure
Max. 95 °C (203 °F)
Relative humidity (operation, storage, and transport)
Annual mean value
≤ 75 %
Continuous operation
15
…
75 %
Continuously for 30 days a year
75
…
95 %
Occasionally on the other days
95
…
100 %
12.15 Further Data
Terminals
Push-in two-tier terminals, pluggable
Conductor cross-sections
0.2
…
1.5 mm
2
AWG 24
…
16,
Fine-stranded with ferrule or solid
Cable types
Shielded cables
Degree of protection according to EN 60529
Input, IP20
Output, IP20
Mechanical load
Shock and vibration according to EN 61373, IEC 61373
Category 1, Class B
Tested by independent test laboratory
MTBF
> 2.6
⋅
10
6
h (383 FIT per channel)
Service life according to EN 50155
20 years, L4 according to EN 50155
Useful operating life according to EN 13849
20 years
Weight
Approx. 170 g