ProLine P16800
30
DIP switch at output
Overview of the functions of the DIP switches at output:
4
• DIP switch output 1 and output 2 (optional)
◦
Choice of current or voltage output
◦
For current output: Choice of high level 14 mA or 20 mA
◦
Choice of standstill detection (middle voltage)
◦
Choice of an inverted or non-inverted output signal
DIP 1
DIP 2
DIP 3
DIP 4
Output value Note
Factory setting
Off
Off
On
On
Low 6/7 mA
High 20 mA
Current output
Off
Off
On
Off
Low 6/7 mA
High 14 mA
Current output
Off
On
On
Off
Low 0 V
High ≈ U
B
Voltage output
Off
On
Off
Off
Low 0 V
High ≈ U
B
Voltage output with standstill detection
On
Off
On
On
Low 20 mA
High 6/7 mA
Current output,
inverted
On
Off
On
Off
Low 14 mA
High 6/7 mA
Current output,
inverted
On
On
On
Off
Low ≈ U
B
High 0 V
Voltage output,
inverted
On
On
Off
Off
Low ≈ U
B
High 0 V
Voltage output with standstill detection,
voltage output,
inverted
See also