41
12.9 Reaction to Input Signals
Input level
U
out
1/2
I
out
1/2
Switching output
SW 1/2
Voltage in-
put
U
Low
Low
Low
Closed
High
High
High
Closed
Middle voltage
Low or high,
depending on input
level/hysteresis
Low or high,
depending on input
level/hysteresis
Closed
f < 1 Hz (with enabled
middle voltage genera-
tion only)
7.2 V
Invalid setting
Closed
Open
Low
Low
Closed
U
S
10
…
33.6 V
Dependent on input
level/hysteresis
Dependent on input
level/hysteresis
Closed
< approx. 9.5 V
Undefined
Undefined
Open
Current in-
put
I
Low
Low
Low
Closed
High
High
High
Closed
< Low
High
High
Open
Open
High
High
Open
Active inversion of the input signals via DIP switch: High and low levels are swapped.
The output signal evaluates middle voltage generation. All input errors are also evaluated in the process.
12.10 Power Supply
Input channel supply
From the respective output circuit, galvanically isolated
Supply of the output channels
V
S
: Output circuit
U
B
: Output driver
Power supply V
S
, U
B
(rail applications)
24 V, SELV, PELV
Power supply V
S
, U
B
(industrial applications)
12
…
24 V, SELV, PELV
Electrical safety
All connected current or voltage circuits must meet the
SELV, PELV, or Area I requirements according to EN 50153.
Overvoltage and undervoltage limits
V
S
: 10
…
33.6 V DC
U
B
: 10
…
33.6 V DC
Interruption class
S1 according to EN 50155 table 6
Switching class
C1 according to EN 50155 table 8
Power consumption via V
S
per channel
Max. 600 mW
Current via U
B
per channel
Max. 5 mA + I
OUT
Max. 5 mA + U
OUT
/R
L
Maximum power conversion P
Max
< 2.2 W
P1681****/**: < 1.1 W
DC ripple factor
5 % according to EN 50155 table 7
Readiness for operation (after switching on the power
supply)
≤ 50 ms
Inrush current at V
S
per channel
With V
S
= 24 V, U
OUT
at R
L
= 1 kΩ
< 0.0002 A
2
per s
Inrush current at U
B
per channel
With U
B
= 24 V, U
OUT
at R
L
= 1 kΩ
< 0.0001 A
2
per s