28
Set the main switch (3-6/1) to “I”. Wait for the
controls to initialize.
Switch on the control unit with the “Control ON”
button (6-3/1) when the “Control ON” button
(6-3/1) starts flashing.
ATTENTION
Under no circumstances may the grinding
program be activated using the “Start / Stop”
button (6-3/2).
Check the direction of rotation of the coolant
pump.
The direction arrow (6-4/1) indicates the direction
of rotation of the coolant pump.
If required, interchange the phases in the power
plug
ATTENTION
Make sure the machine is correctly connected
to the power supply.
If the connection to the voltage supply is
incorrect, the grinding belts and cam disc can
rotate in opposite direction of the prescribed
direction. Incorrect direction of rotation can
result in serious injuries.
6. Commissioning
Figure 6-3
Control panel