Figure 6-2
Compressed air connection
1
Figure 6-1
Set coolant hoses
1
1
3
2
27
All work on the machine may only be performed by trained personnel.
The locally applicable safety and accident prevention regulations must be
observed.
Connect compressed air only when the doors are closed.
Never cut off the compressed air while the knives are clamped.
This can result in serious injury.
CAUTION
Fill the water basin (3-2/3) to 3 cm below the rim with water.
Open the safety doors.
Set the coolant hoses (6-1/1) as illustrated in the
figure. The gap from the rear grinding wheel (6-
1/2) and the front grinding wheel (6-1/3) should
be approx. 5 cm. The coolant hoses must not
come into contact with the grinding wheels.
ATTENTION
Observe the minimum gap between the
coolant hoses and the grinding wheels, as
the grinding wheel moves forward when
grinding.
Connect the power plug (CEE plug) to the power socket provided on site (3x 400 V, 32 A).
Plug in the compressed air hose at the compressed
air port (6-2/1).
Close the safety doors.
6. Commissioning