SECTION 7
HIGH PRESSURE WATER
May 2003
p. 7-3
49831951
7.2.1
HP & LP Water Piping
Disconnect from/Reconnect to Waterjet Pump
Before performing maintenance on the waterjet
pump observe electrical LOCK OUT/TAG OUT
procedures.
1.
Loosen and remove HP Piping attached to the discharge HP check
valve. Move tubing to clear work area.
2.
For servicing the discharge HP check valve on the intensifier
assembly, refer to section 7.3.1. “Discharge HP Check Valve”.
Note that the sealing head can be removed with the discharge HP
check valve attached.
3.
Disconnect LP water at end flange. Note that to service the sealing
head, including the inlet HP check valve, the tie bolts must be
loosened allowing removal of the end flange.
4.
With the HP piping and the LP cutting water plumbing disconnected,
the following operations can be performed:
•
HP cylinder can be removed from hydraulic cylinder head
•
HP plunger seal can be serviced
After the pump has been reassembled, then the HP water piping and
LP water disconnect are reinstalled as follows:
5.
Slide inlet water collar over sealing head until it rests against the
head nut. Connect LP inlet water quick disconnect to collar.
6.
Install the HP water piping to the intensifier. Check HP fittings for
proper collar position (1 to 1-1/2 threads exposed) and for adequate
thread lubricant (High Purity Goop). Turn on cutting water supply
and check for low-pressure leaks.
Check that all proximity switches are properly
installed and secured prior to starting the motor.
Failure to tighten proximity switch hold down screws
(2 each per proximity switch) will result in hydraulic
oil spraying in general directions.
7.
Start the waterjet pump. Operate at low pressure (without a cutting
orifice) to flush the HP passages, then operate at high pressure with
orifice installed to check for leaks.
WARNING
!
CAUTION
!
Summary of Contents for STREAMLINE SL-IV PLUS
Page 44: ...SECTION 6 LOW PRESSURE WATER May 2003 6 4 05148390 Figure 6 2 LP Cutting Water Supply Circuit ...
Page 78: ...SECTION 7 HIGH PRESSURE WATER May 2003 p 7 30 49831951 ...
Page 82: ...SECTION 8 ELECTRICAL SYSTEM Aug 2002 p 8 4 49836323 ...
Page 111: ...SECTION 12 PARTS LISTS July 2003 page 12 5 49836349 ...
Page 113: ...SECTION 12 PARTS LISTS July 2003 page 12 7 49836349 ...
Page 115: ...SECTION 12 PARTS LISTS July 2003 page 12 9 49836349 ...
Page 117: ...SECTION 12 PARTS LISTS July 2003 page 12 11 49836349 ...
Page 119: ...SECTION 12 PARTS LISTS July 2003 page 12 13 49836349 ...
Page 121: ...SECTION 12 PARTS LISTS July 2003 page 12 15 49836349 ...
Page 123: ...SECTION 12 PARTS LISTS July 2003 page 12 17 49836349 ...
Page 125: ...SECTION 12 PARTS LISTS July 2003 page 12 19 49836349 ...
Page 127: ...SECTION 12 PARTS LISTS July 2003 page 12 21 49836349 ...
Page 129: ...SECTION 12 PARTS LISTS July 2003 page 12 23 49836349 ...
Page 131: ...SECTION 12 PARTS LISTS July 2003 page 12 25 49836349 ...
Page 133: ...SECTION 12 PARTS LISTS July 2003 page 12 27 49836349 ...
Page 135: ...SECTION 12 PARTS LISTS July 2003 page 12 29 49836349 ...
Page 137: ...SECTION 12 PARTS LISTS July 2003 page 12 31 49836349 ...
Page 139: ...SECTION 12 PARTS LISTS July 2003 page 12 33 49836349 ...
Page 141: ...SECTION 12 PARTS LISTS July 2003 page 12 35 49836349 ...
Page 143: ...SECTION 12 PARTS LISTS July 2003 page 12 37 49836349 ...
Page 145: ...SECTION 12 PARTS LISTS July 2003 page 12 39 49836349 ...
Page 146: ......
Page 147: ......