SECTION 6
LOW PRESSURE WATER
May 2003
6-2
05148390c
•
High temperature at the booster pump outlet (switch (2).
•
If the motor does not run for 2 minutes, the solenoid valve (11) will
shut off. To re-open the valve, press F6.
Note that pressure gages for T series KMT Waterjet pumps are installed
in a frame leg for easy access. Pressure gages provide a qualitative
measure of LP water system performance, while pressure switches on the
T&Q series pumps provide automatic shutdown protection against out of
tolerance conditions.
6.2.1 Normal Operating Condition
During normal operation, the low pressure water system maintains the
following conditions:
•
Filter pressure drop (gage reading 4 minus 6) not more than 1 bar (15
psi)
•
Booster pump inlet pressure greater than 2 bar (30 psi), (T and Q
series).
•
Booster pump discharge pressure gage reading 8.0-8.3 bar (115-120
psi)
•
Intensifier LP cutting water supply pressure greater than 4 bar (60
psi), (T and Q series).
•
Water at booster pump outlet maintained at less than 128 deg-F.
NOTE
While the intensifier assembly reverses direction, the booster pressure
will fluctuate slightly above and below the normal setting. Pressure
fluctuation greater than 2 bar (30 psi) may indicate inadequate water
supply to unit, or poor booster pump performance.
6.2.2 Operation
The cutting water enters the pump through port “B”. When the
CONTROL POWER-- ON button on the operator control panel is
activated, solenoid valve (11) opens allowing water to flow through filter
assembly (5), then to the inlet of the booster pump (1). The booster
pump increases cutting water supply pressure to 8 bar (120 psi) to
assure proper supply to both intensifier inlet check valves (13).
Pressurized water from the booster pump is supplied to manifold (18).
From this manifold, cutting water is routed to the inlet check valves (13)
of the intensifier. Note that if a redundant intensifier is installed, the
inlet cutting water must be manually disconnected from the inactive
intensifier, then connected to the inlet check valves of the inactive
intensifier.
Summary of Contents for STREAMLINE SL-IV PLUS
Page 44: ...SECTION 6 LOW PRESSURE WATER May 2003 6 4 05148390 Figure 6 2 LP Cutting Water Supply Circuit ...
Page 78: ...SECTION 7 HIGH PRESSURE WATER May 2003 p 7 30 49831951 ...
Page 82: ...SECTION 8 ELECTRICAL SYSTEM Aug 2002 p 8 4 49836323 ...
Page 111: ...SECTION 12 PARTS LISTS July 2003 page 12 5 49836349 ...
Page 113: ...SECTION 12 PARTS LISTS July 2003 page 12 7 49836349 ...
Page 115: ...SECTION 12 PARTS LISTS July 2003 page 12 9 49836349 ...
Page 117: ...SECTION 12 PARTS LISTS July 2003 page 12 11 49836349 ...
Page 119: ...SECTION 12 PARTS LISTS July 2003 page 12 13 49836349 ...
Page 121: ...SECTION 12 PARTS LISTS July 2003 page 12 15 49836349 ...
Page 123: ...SECTION 12 PARTS LISTS July 2003 page 12 17 49836349 ...
Page 125: ...SECTION 12 PARTS LISTS July 2003 page 12 19 49836349 ...
Page 127: ...SECTION 12 PARTS LISTS July 2003 page 12 21 49836349 ...
Page 129: ...SECTION 12 PARTS LISTS July 2003 page 12 23 49836349 ...
Page 131: ...SECTION 12 PARTS LISTS July 2003 page 12 25 49836349 ...
Page 133: ...SECTION 12 PARTS LISTS July 2003 page 12 27 49836349 ...
Page 135: ...SECTION 12 PARTS LISTS July 2003 page 12 29 49836349 ...
Page 137: ...SECTION 12 PARTS LISTS July 2003 page 12 31 49836349 ...
Page 139: ...SECTION 12 PARTS LISTS July 2003 page 12 33 49836349 ...
Page 141: ...SECTION 12 PARTS LISTS July 2003 page 12 35 49836349 ...
Page 143: ...SECTION 12 PARTS LISTS July 2003 page 12 37 49836349 ...
Page 145: ...SECTION 12 PARTS LISTS July 2003 page 12 39 49836349 ...
Page 146: ......
Page 147: ......