PCB PARAMETERS
The parameters stored on the PCB are essential for the correct operation.
The following parameters are already stored during the testing of the appliance directly in the factory; these parameters
are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover
srl so as not to impair the operation of the appliance.
The company shall not be held liable for any damage caused by the incorrect entry of parameters.
Parameter tables DIVA SLIM AIR
“CLEANER SETTINGS” parameters - Model DSA
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P1
Pr51
M10 – 01 – 01
ON time for brazier cleaning gear motor
CLEANING TIME
Seconds
0 – 120”
13
Pr52
M10 – 01 – 02
Time from switching off after which the brazier cleaning cycle starts
CLEANER DELAY
Minutes
1 – 15
6
Pr53
M10 – 01 – 03
Time from switching on after which the brazier cleaning cycle starts
CLEANER STAND-BY
Hours
1 – 24
9
“DUCTING SETTINGS” parameters - Model DSA
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P1
Pr55
M10 – 03 – 01
Enables ducting operation
ENABLE DUCT.
Off / Mode
Off
S1 – S2 – S1+2
T1 – T2 – T1+2
A1 – A2 – A1+2
Off
Pr56
M10 – 03 – 02
Allows for choosing whether the ducted air fans can be switched “OFF”.
DUCTED OFF
On – Off
On – Off
Off
Pr57
M10 – 03 – 03
Heat exchanger 2 (ducting 1) in power 1 work phase
DUCT.1 SPEED-S1
Volt
65 – 225
65
Pr58
M10 – 03 – 04
Heat exchanger 2 (ducting 1) speed in power 2 work phase
DUCT.1 SPEED-S2
Volt
65 – 225
65
Pr59
M10 – 03 – 05
Heat exchanger 2 (ducting 1) in power 3 work phase
DUCT.1 SPEED-S3
Volt
65 – 225
65
Pr60
M10 – 03 – 06
Heat exchanger 2 (ducting 1) in power 4 work phase
DUCT.1 SPEED-S4
Volt
65 – 225
65
Pr61
M10 – 03 – 07
Heat exchanger 2 (ducting 1) in power 5 work phase
DUCT.1 SPEED-S5
Volt
65 – 225
65
Pr62
M10 – 03 – 08
Heat exchanger 3 (ducting 2) in power 1 work phase
DUCT.2 SPEED-S1
Volt
65 – 225
65
Pr63
M10 – 03 – 09
Heat exchanger 3 (ducting 2) in power 2 work phase
DUCT.2 SPEED-S2
Volt
65 – 225
65
Pr64
M10 – 03 – 10
Heat exchanger 3 (ducting 2) in power 3 work phase
DUCT.2 SPEED-S3
Volt
65 – 225
65
Pr65
M10 – 03 – 11
Heat exchanger 3 (ducting 2) in power 4 work phase
DUCT.2 SPEED-S4
Volt
65 – 225
65
Pr66
M10 – 03 – 12
Heat exchanger 3 (ducting 2) in power 5 work phase
DUCT.2 SPEED-S5
Volt
65 – 225
65
Parameters “VARIOUS SETTINGS” - Mod. DSA
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P1
Pr38
M10 – 04 – 01
Re-ignition block
RESTART BLOCK
Minutes
0 – 10
5
Pr39
M10 – 04 – 02
Time for considering the device off
OFF TIME
Minutes
0 – 20
10
Pr40
M10 – 04 – 03
Pre-loading time in ignition
PRE-LOAD START
Seconds
0 – 255
210
Pr41
M10 – 04 – 04
Stand-by time after pre-loading
AFTER PRE-LOAD
Seconds
0 – 255
120
Pr42
M10 – 04 – 05
Extractor speed in pre-loading phase
PRE-LOAD SMOKE
SPEED
Rpm
350 – 2800
2100
Pr43
M10 – 04 – 06
Temperature delta on “SET ROOM” for automatic switching on/off
DELTA ON-OFF
°C
0.0 – 10.0
1.0
Pr44
M10 – 04 – 07
Automatic switch-off delay (timer after reaching “SET ROOM”)
AUTO OFF DELAY
Minutes
2 – 120
10
Pr45
M10 – 04 – 08
Power change delay
POWER CHANGE
Seconds
0 – 240
60
Pr46
M10 – 04 – 09
Heat exchanger 1 speed (primary) in the switch-off phase
AIR SPEED OFF
Volt
65 – 225
225
Pr47
M10 – 04 – 10
Keypad lock enable
KEY LOCK
On – Off
On – Off
Off
Pr48
M10 – 04 – 11
Time after which an alarm is triggered in the event of a blackout
BLACK OUT TIME
Seconds
0 – 60
30
Pr49
M10 – 04 – 12
Time after which the “NO PELLET” alarm triggers In case of “PELLET
RESERVE”
RESERVE ALARM
Minutes
1 – 180
60
Pr50
M10 – 04 – 13
Enabling of the pellet level sensor (only on configured models)
PELLET RESERVE
On – Off
On – Off
Off
Summary of Contents for DIVA SLIM
Page 1: ...ENGLISH DIVA SLIM AIR pellet stove INSTALLATION USE MAINTENANCE AND HELPFUL TIPS ...
Page 2: ......
Page 9: ...DIVA SLIM AIR PELLET STOVE 7 EN Rev 1 0 Overall dimensions ...
Page 49: ...DIVA SLIM AIR PELLET STOVE 47 EN Rev 1 0 ...
Page 50: ...DIVA SLIM AIR PELLET STOVE 48 EN Rev 1 0 ...