![klover DIVA SLIM Installation, Use, Maintenance And Helpful Tips Download Page 15](http://html1.mh-extra.com/html/klover/diva-slim/diva-slim_installation-use-maintenance-and-helpful-tips_1978951015.webp)
DIVA SLIM AIR PELLET STOVE
13
EN - Rev. 1.0
If the flue is old or too large (internal diameter greater than 15 cm), it must be ducted using a stainless steel pipe that is
suitably insulated (with rock wool or vermiculite) and sized according to the route. The connection to the flue must be
appropriately sealed.
When assembling the flue, there must be no more than 4 direction changes, including the initial T-shaped
fitting.
Chimney
The chimney is a device crowning the flue, used to ease dispersion of combustion products.
It must satisfy the following requirements:
-
It must have a usable outlet cross-section which cannot be smaller than double that of the flue onto which it is
inserted;
-
It must be shaped in such a way as to prevent rainwater or snow from entering the flue;
-
It must be built in such a way as to ensure the discharge of combustion by-products even in the event of winds from
every direction and inclination.
The outlet height (where height refers to the top of the flue, regardless of any chimney stacks) must be outside of the so-
called reflux zone, in order to prevent the formation of counter-pressures preventing the free discharge of combustion
by-products into the atmosphere.
It is therefore necessary that the minimum heights - indicated in the following diagrams - are observed:
Ø 80 mm
Ø 80 mm
INSPECTION
M
INIM
U
M
0
.5
m
80 mm
INSPECTION