32
Change the oil after the first 50 hours of operation, and then every 100 hours of operation. If
the machine has run less than 100 hours per season, then the oil must be replaced when
removing the mower from storage.
Oil replacement is required at operating temperature, which allows to maximize the cavity of
the cutting device from the waste oil.
The amount of oil poured into the crankcase ZTT-2.8 - 2.8 liters (2.5 kg); ZTT-3.2 - 4.5 liters
(4 kg);
WARNING: It is strictly forbidden to fill oil more than necessary. Both the
insufficient and excessive amount of oil in the drive shaft of the cut device will lead
to its overheating and subsequent failure!