![KKT KOLBE WS1503S User Manual Download Page 43](http://html1.mh-extra.com/html/kkt-kolbe/ws1503s/ws1503s_user-manual_1974633043.webp)
43
Installation / Technical data
EN
554
54
1
124.5
541
10.5
6
19.5*/20.5
595
505
* Colour-fronted appliances
An intermediate floor is not required.
Building-in dimension including
mains supply cable connection
Connection cable L = 1000 mm
Note:
• The maximum power of compact appliances is 3350W.
• The power cord can only be routed through the hole
in the bottom or the side wall of the cabinet to avoid
touching the back shell of the appliance.
Electrical connection
Important Information
•
The appliance is fitted with a plug and must only be
connected to a properly installed earthed socket.
•
Only a qualified electrician who takes the approriate re
-
gulations into account may install the socket or replace
the connecting cable.
• If the plug is no longer accessible following installati-
on, an all-pole isolating switch must be present on the
installation side with a contact gap of at least 3 mm.
• Contact protection must be ensured by the installation.
Technical data
Model
WS1503S
Colour
black
Power supply
220-240 V ~ 50/60 Hz
Total connected load
1000 W
Capacity
14 L