50
Table 1.0 Command ID
Data Byte
Data Type
Byte details
7 ------- 0
Data Details
$04 (4) Transmit/Receive Patch Edit
Buffer Dump
Null x 2 + 128 data bytes
2 x Null + 128 bytes data
2 x null bytes sent followed by 128 bytes of data in the
following format
$00-$13 (0-19) = Patch Name
Ascii Bytes
Patch Name
$14 (20)=DCO Wave/Range
0000zyxx
xx =
DCO Range
00=16'
01=8'
10=4'
y =
Saw On/Off (set=on)
z =
Pulse On/Off (set=on)
$15 (21)=DCO Env Amount Hi
000xxxxx
$16 (22)=DCO Env Amount Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$17 (23)=DCO LFO Amount Hi
000xxxxx
$18 (24)=DCO LFO Amount Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$19 (25)=DCO Bend Mod Amount Hi 000xxxxx
$1a (26)=DCO Bend Mod Amount Lo 0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$1b (27)=DCO Bend LFO Mod
Amount Hi
000xxxxx
$1c (28)=DCO Bend LFO Mod
Amount Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$1d (29)=DCO PWM Amount Hi
000xxxxx
$1e (30)=DCO PWM Amount Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$1f (31)=DCO Control
0000000u
0vwxxxyz
z =
DCOENV(0=ENV1,1=ENV2)
y =
DCOLFO(0=LFO1,1=LFO2)
xxx =
PWM Source
000=Manual
001=LFO1
010=LFO2
011=ENV1
100=ENV2
w =
DCO ENV(0=Norm,1=Inverted)
v =
PWM ENV(0=Norm,1=Inverted)
u =
LFO POL(0=Norm,1=Inverted)
$20 (32)=Sub Level Hi
000xxxxx
www.kiwitechnics.com
Kiwi-106 Upgrade User Manual v204