15
Kiwi 106 Menu System
Midi CC
Bank 8
The Kiwi106 can be optionally disable
Midi CC input and output.
'01'=
Disabled
'02' = Midi CC Input Enabled
'03' =
Midi CC Input & Output Enabled
Midi Sysex
Patch 1 – (Display 9)
Sysex Input can be optionally
disabled.
Note – The sysex ID request will work
even if sysex is diabled
'OF'= Off
'On' = On
Midi Clock
Patch 2 – (Display 10)
The Kiwi106 can optionally output the
internally generated clock as a midi
clock command.
'OF'= Off
'On' = On
Arp Clock Divide
Patch 3 – (Display 11)
The Kiwi106 Arpeggiator Clock can be
Divided from the Master Clock Source.
'01'=Half Note (48/Step)
'02'=Quarter note (24/Step)
'03'=8th note (12/Step)
'04'=8th note, 1/2 swing (14,10/Step)
'05'=8th note, full swing (16,8/Step)
'06'=8th note triplets (8/Step)
'07'=16th note (6/Step)
'08'=16th note, 1/2 swing (7,5/Step)
'09'=16th note, full swing (8,4/Step)
'10'=16th note triplets (4/Step)
'11'=32nd note (3/Step)
'12'=32nd note triplets (2/Step)
'13'=64th note triplets (1/Step)
Seq Clock Divide
Patch 4 – (Display 12)
The Kiwi106 Sequence Clock can be
Divided from the Master Clock Source.
'01'=Half Note (48/Step)
'02'=Quarter note (24/Step)
'03'=8th note (12/Step)
'04'=8th note, 1/2 swing (14,10/Step)
'05'=8th note, full swing (16,8/Step)
'06'=8th note triplets (8/Step)
'07'=16th note (6/Step)
'08'=16th note, 1/2 swing (7,5/Step)
'09'=16th note, full swing (8,4/Step)
'10'=16th note triplets (4/Step)
'11'=32nd note (3/Step)
'12'=32nd note triplets (2/Step)
'13'=64th note triplets (1/Step)
Pattern Clock Source
Patch 5 – (Display 13)
The Kiwi106 Pattern Clock can be
from the Arpeggiator or Sequence
Clocks.
'01'=
ARP Clock
'02' = SEQ Clock
Pattern Destination
Patch 6 – (Display 14)
The Pattern Destination can send the
pattern to the VCF Cutoff or the VCA
Level or Both
'01'=
VCF Cutoff
'02' =
VCA Level
'03' =
Both
Dynamics Mode
Patch 7 – (Display 15)
The Midi Dynamics can be enabled or
disabled for the VCF & VCA. If midi
dynamics are disabled notes will
sound at the internal level.
The left digit is the VCF and the right
digit is the VCA and all combinations
can be set.
'0' =
Off
'1' =
Low Level
'2' =
Mid Level
'3' =
High Level
Note - Dynamics is a Patch parameter
and not a global parameter.
www.kiwitechnics.com
Kiwi-106 Upgrade User Manual v204