87
Table 7-4 "Minor Failure/ Warning Error" Type Summary
LED Display
Name
EF
Forward/reverse command simultaneous input
to
EF1 to EF7
External error (Input terminal S1 to S7)
Hbb
Inputting a safety signal
HCA
Current warning
oH
Heat sink overheat
Ov
Main circuit overvoltage
CrST
Reset during driving command input
Uv
Main circuit low voltage
Table 7-5 "Operation Error" Type Summary
LED Display
Name
oPE02
Invalid parameter setting range
Table 7-6 "Error" Display Details and Remedies
LED Display
Error name
CF
Control error
Torque limit took 3 seconds or more in succession during
deceleration/stop
Cause
Measure
Load inertia is high.
- Adjust the parameters used among C1-02, -04, -06, -08 (deceleration
time).
- Lower the frequency command to the minimum output frequency for
deceleration, and then turn off the driving command.
LED Display
Error name
CPF03
EEPROM failure
EEPROM does not function
CPF06
EEPROM data error
Data stored in the EEPROM is erroneous.
Cause
Measure
Control circuit is damaged.
Turn on/off the power supply to check operation.
-If the error occurs again, replace the VFD
LED Display
Error name
CPF07
Terminal board communication error
Failure with the terminal board
Cause
Measure
Failure between the terminal board and
control board
-Turn off the power supply of the VFD and re-connect the control circuit
terminal.
Summary of Contents for Harrington RY Series
Page 15: ...15 2 3 Part Names Figure 2 1 RY Part Names...
Page 42: ...42 Figure 3 20 Hoist Upper and Lower Limit Switch ULLS...
Page 57: ...57 Table 5 8 Various shapes that require the wire rope to be replaced...
Page 67: ...67 Table 6 9 Motor Brake Gap Capacity Code Brake Gap G inch mm RY030 RY050 0 032 0 8...
Page 104: ...104 9 3 Trolley Frame Parts Figure 9 3 Trolley Frame Parts...
Page 112: ...112 9 10 Hoist Motor Parts Figure 9 10 Hoist Motor Parts...
Page 114: ...114 9 11 Trolley Motor Parts Figure 9 11 Trolley Motor Parts...
Page 116: ...116 9 12 Control Panel Box Parts Figure 9 12 Control Panel Box Parts...