Table 3-11
Load Limiter Inactivation Setting Values
200V = 208 – 230V/400V = 415 – 460V
Capacity
(T)
Product Code
LL Inactivation
Settings
200V
400V
S1-38
S1-41
S1-38
S1-41
Low
Speed
High
Speed
Low
Speed
High
Speed
3
RYU030A
156
163
161
165
5
RYU050B
153
157
164
158
8. Press
to confirm the new setting.
9. The display will automatically return to the parameter setting screen (shown in the figure
on the right, in the case of S1-38: low speed). Follow Step 4) and later to set S1-41 for the
high-speed parameter.
10. After setting both the low- and high-speed parmeters, press
until the diplay returns
to the initial, default screen. (As in Step 1.)
•
After the change is completed, be sure to perform the load test with the condition in which the
LL will not be activated.
•
Make sure to reset the activation parameter values to the default ones after the load test is
finished.
•
If the values are not reset, the LL will not be activated properly.
THE LOAD LIMITER MUST BE SET TO FACTORY SPECIFICATIONS (Table 3-10)
PRIOR TO THE HOIST BEING PLACED INTO SERVICE. FAILURE TO DO SO WILL PREVENT
THE HOIST FROM FUNCTIONING PROPERLY IN THE EVENT OF AN OVERLOAD CONDITION.
Summary of Contents for Harrington RY Series
Page 15: ...15 2 3 Part Names Figure 2 1 RY Part Names...
Page 42: ...42 Figure 3 20 Hoist Upper and Lower Limit Switch ULLS...
Page 57: ...57 Table 5 8 Various shapes that require the wire rope to be replaced...
Page 67: ...67 Table 6 9 Motor Brake Gap Capacity Code Brake Gap G inch mm RY030 RY050 0 032 0 8...
Page 104: ...104 9 3 Trolley Frame Parts Figure 9 3 Trolley Frame Parts...
Page 112: ...112 9 10 Hoist Motor Parts Figure 9 10 Hoist Motor Parts...
Page 114: ...114 9 11 Trolley Motor Parts Figure 9 11 Trolley Motor Parts...
Page 116: ...116 9 12 Control Panel Box Parts Figure 9 12 Control Panel Box Parts...