4.3 Specifications and dimensions
Power supply
230V-50Hz
Type
Single speed type
Dual speed type
Dual speed cylinder type
Model
ED06S ED10S ED18S ED16S ED24S
ED48S
ED06S
ED10S
ED18S
ED16S
ED24S
ED48S ED06S ED10S ED18S
ED16S
ED24S
WLL
(kg) 60 100 180 160 240 480 60 100 180 160 240 480 60 100 180 160 240
Motor
output
(W)
300 600 300 600 300
600
Intermittent
duty
%
ED
30 20
30
30 20
30
30 20 30
Max. starting frequency
(Time per hour)
180 120
180
180 120
180
180 120 180
Rated Current (A)
230V
3
5
3
5
3
5
Lifting speed (m/min)
High 20.1 12.5 7.7 19.2 12.9 6.7 20.1 12.5 7.7 19.2 12.9 6.7 20.1 12.5 7.7 19.2 12.9
Low - - - - - - 4 3 3 4 3 2 4 3 3 4 3
Standard lift
(m)
3
3
1.8
Push button cord length: L
(m)
2.5
2.5
-
Load chain diameter
(mm)
4
4
4
Net weight
(kg)
11.5
15.5
21(21.5)*1
12.0 16.0
21(21.5)*1
14.5 18.5
Min. distance between hooks: C (mm)
315
330
520
315
330
520
945
960
IP
(Degree of protection)
IP54
IP44
Insulation
F
Dimensions (mm)
a
364 428 364 428 364
428
d
187 205 187 205 187
205
e
177 223 177 223 177
223
f
205 219
229
205 219
229
205 219
h
125 135
155
125 135
155
125 135
i
80 84
74
80 84
74
80 84
g 25 24 25 24 25
j 25 24 25 24 25
k
340 362
454
340 362
454
340 362
m 92 149 92 149 92
n 73 104 73 104 73
・
WLL: Indicates maximum mass (working load limit) which a hoist is designed to support in general service.
・
Control: Direct voltage control.
・
The lifting speed is equal to the average value of the lifting/ lowering speed at the rated load capacity. The speed will vary according to the load.
Actual power source voltage should not exceed max. allowable voltage: 264V
The lifting speed varies according to the actual power source voltage as shown in following table.
Single speed type and
Dual speed type
Dual speed cylinder type
CAUTION