— 27 —
Situation Condition
Cause
Remedy
Brake
slippage.
・
Braking distance is too long,
even under no load conditions.
・
Motor has become
demagnetized, owing to
too frequent use.
・
Replace with a normal
one.
・
Improper contact of
electromagnetic
contactors.
・
Deteriorated resistor for
dynamic braking.
・
The load cannot be held at the
level when stopping operation.
・
Improper gear oil use.
・
Replace the specified gear
oil.
・
Within rated load, lifting/
lowering speed is slow.
・
Deterioration of clutch
brake.
・
Replace the set of
mechanical brake with
friction clutch.
Oil leakage.
・
Oil leakage from case joint and
chain guide.
・
Defective gear case
packing/oil seal.
・
Replace with a normal
one.
・
Loosened assembly bolts.
・
Fasten with normal
torque.
・
Leakage from oil plug.
・
Loosened oil plug.
・
Fasten oil plug.
A clicking
sound is
heard from
the load chain
during lifting.
----------
・
Wear of load sheave.
・
Replace with a normal
one.
・
Wear of load chain.
・
Rust on load chain.
Electric
shock.
----------
・
Accumulation of
moisture/foreign matter
on electrical instruments.
・
Remove moisture/foreign
matter.
・
Improper grounding.
・
Secure correct grounding.
Ask your local Kito dealer to repair.
For maintenance, a fuse shown in the table is attached in the
controller cover (the capacity/ name plate side) as a spare.
Fuses for maintenance
WLL (kg)
Speed type
Fuse rating
(A)
Nos.
per
hoist
60, 100, 180
Single 5 2
Dual
5 2
0.1 1
160, 240,
480
Single 10 2
Dual
10 2
0.1 1