6-1
DIAGNOSIS & TROUBLESHOOTING
DIAGNOSIS
PRE-DIAGNOSTICS CHECKS
• Confirm the refrigerator and freezer tem-
peratures before beginning other checks.
• See if the compressor, evaporator, and
condenser fans are running.
• Check the position of the air door.
DIAGNOSTICS MODE
The Diagnostics Mode is used to:
• Check the refrigerator & freezer ther-
mistors.
• Operate the evaporator fan motor at 3000
rpm.
• Operate the condenser fan motor and com-
pressor.
• Check the defrost bimetal and heater.
To enter the Diagnostics Mode, the control
must be turned on, and be in a normal cooling
mode.
Power
On/Off
Warmer
Colder
Warmer
Colder
FREEZER
REFRIGERATOR
WATER FILTER
PERCENT LEFT
RESET
°
C
SELECT
Both the Power On/Off and the Water Filter
Reset keys must be functional. The refrigera-
tor display shows the step number. The results
of the checks are displayed on the water filter
status indicator. After 20 minutes, the control
will default from the Diagnostics Mode to a
normal cooling mode.
To enter the diagnostics mode:
• Press and hold the Water Filter Reset
keypad, and then immediately press and
hold the Power keypad. Continue to press
both keypads for 3 seconds, or until you
hear a beep.
To advance the diagnostics sequence:
• To advance to the next step in the se-
quence, press and hold the Water Filter
Reset key for 2 seconds, or until you hear
a beep. The Diagnostics Chart on the next
page shows the step number and the com-
ponent being tested in each step.
Summary of Contents for KSSC36FKB00
Page 62: ...5 8 NOTES ...
Page 66: ...6 4 NOTES ...
Page 67: ...7 1 WIRING DIAGRAMS STRIP CIRCUITS WIRING DIAGRAM BOTTOM MOUNT P5 P7 P6 P2 P3 P4 ...
Page 68: ...7 2 WIRING DIAGRAM SIDE BY SIDE MODELS P5 P7 P6 P2 P3 P4 OPTIONAL DISPENSER MODELS ONLY ...
Page 72: ...7 6 NOTES ...
Page 73: ...7 7 NOTES ...
Page 74: ...7 8 NOTES ...
Page 76: ......