4-7
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
REASSEMBLY NOTE: Be sure to reconnect
the green ground wires; one to the compressor
terminal, and the other to the chassis (see the
previous steps).
7.
To remove the main control board as-
sembly:
a) Remove the unit compartment cover
(see pages 4-2 & 4-3 for the proce-
dures).
b) Remove the two hex-head screws from
the rear of the main control board as-
sembly enclosure, and position it so
you can access the board.
c) Remove the wire connectors from the
main control board assembly.
Wire Connectors
Screws At Rear Of Enclosure
d) Remove the main control board from
the five standoffs. Press in on the lock-
ing tab on each standoff to release the
board.
Press Locking Tab
On Standoff