30
FORCE RESET
NOTES:
IMPORTANT!
•
You must connect the
Door input
and the
Ignition input
for Force Reset to work (see pages 7, 9 & 10 for wiring details). Failure
to connect both the Door input and Ignition Input will prevent you from
disarming system manually. And you will need to disarm manually
if you lose your trasmitter or if the transmitter battery dies or if your
transmitter has been lost from memory somehow.
The siren will go off for a full 30 seconds when you open the door
•
(unless
the system was armed in Silent Mode)
. When you open a door, the sys-
tem will trigger and the Status LED will flash rapidly. The Status LED
will then shut off when the system has been succesfully disarmed.
If you enter an incorrect Force Reset Code, or if you fail to enter your
•
code within 30 seconds, the siren will shut off for 8 seconds and then
sound for another 30 seconds (because the door is open). You must try
to enter your Reset Code again during the next 30 seconds. If you fail
again, you must wait until the siren stops and starts again. DO NOT
CLOSE THE DOOR, or the siren will eventually stop and the system
will not recognize your Reset Code. You can close the door once you
have disarmed the system.
Don’t worry if the siren doesn’t stop immediately after you enter your
•
Reset Code. The system forces the siren to go off for the full 30 seconds
for security.