Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for
Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in
Canada.
THE VENTED GAS FIREPLACE HEATERS IN THIS MANUAL MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER
FIRST SALE IN THE USA.
THE VENTED GAS FIREPLACE HEATERS IN THIS MANUAL MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES IN
CANADA.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National
Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8 ga. copper wire using a serrated or star washer to
penetrate paint or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed millivolt thermostat. In USA see local
codes.
Warning: Do not compromise the structural integrity of the manufactured home wall, floor
or ceiling, during installation of appliance or venting.
Appliance Must Be Secured To
Structure Using Supplied Nailing
Tabs And Or Fastened To Floor.
Use Existing Hole Or Remove
Existing Screw To Mount Ground
Wire (Nailing Tab Screw).
Serrated Or Star Washer
Ground Wire From Appliance To Steel
Chassis Of Mobile Home. USE 8GA
COPPER WIRE.
9
Summary of Contents for marquis ZCV39LPE2
Page 62: ...Gas Conversion for Modulator PART C 62...
Page 67: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 67...
Page 68: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 68...
Page 75: ...Proflame 2 Remote Control 75...
Page 77: ...77...