General Vent Installation Information
This gas appliance is approved to be vented either through
the side wall or vertically through the roof. Only Kingsman
Flex (Z-Flex) Venting Kits and components specifically
approved and LABELED for this stove may be used. This
appliance is also approved for use with M & G-Duravent
Direct Vent system (Duravent Pro), BDM Pro Form Direct
Vent, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct,
Metal Fab Sure-Seal DV and Selkirk Direct Temp.
Rigid or Hard Pipe
When using M & G Duravent, Ameri-Vent pipe, BDM Pro
Form Direct Vent, ICC Excel Direct, Metal Fab Sure-Seal DV
and or Selkirk Direct Temp a Duravent hard pipe adapter
must be used (part # ZDVDFA for fire- places and part #
ZDVDKA for Stoves, Serenity and ZDV3624B). Follow
installation instructions provided by M & G Duravent/Ameri-
Vent/Selkirk Direct Temp, ICC Excel Direct, and Metal Fab
Sure-Seal DV for installation of pipe and adhere to the
clearance to combustibles provided in this manual. Apply a
bead of Mill Pac high temp sealant to all joints of pipes,
adapters and termination, when using Kingsman Flex (Z-Flex)
venting and M & G Duravent venting.
Flex Pipe Venting
Kingsman Flex pipe is shipped in unexpanded length. When
installing pipe expand the lengths. Pipe can be expanded to
twice their lengths e.g., 4ft. to 8ft. Fully expand pipe and cut
off excess. Do not use more than 2 couplers to extend short
pipes. Single sections are preferred in an installation
attaching at the fireplace and termination.
Place the spring spaces provided approximately every two
feet to stabilize 4” flex in the center of 7” flex. When forming
bends place spring in bend or before and after. (See Fig. 1).
Horizontal runs require support metal straps every 2 feet. In
offset installation support straps should be used to stabilize
pipe.
Expand 4” and 7” flex pipe to the point that the 7” protrudes
approximately 2 to 3 inches past outer wall and the 4” flex
protrudes approximately 2 to 3 inches past the 7” flex
. (See
Fig. 1). Attach the 4” pipe to the termination first and secure
with sealant and screws then attach the 7” flex to the
termination with caulking and screws. Termination may then
be moved back to the outer wall and attached to home
screwing into the framing. Silicone around termination to
waterproof. If siding shield is going to be used attach this
using same attaching hole as the top of termination after
termination has been caulked for water proofing.
Use Hi Temp Sealant
Apply a bead of Mill Pac high temp sealant to all joints and
use four screws to secure each pipe at fireplace, termination
and any joint if joining any sections of pipe.
Preventing Moisture Problems
Insulate wall thimbles and support boxes for vertical attic
terminations with non-combustible mineral wool Insulation
(Roxul, Rockwool, Thermafiber UltraBatt, etc.).
Attach and seal the outer perimeter of the wall thimble or
support box to the existing vapor barrier.
FRAMING DIMENSION
Combustible Wall
Cut an
11”
hole through exterior wall and frame as
shown.
Non-Combustible Wall
Cut or drill
8”
or 204mm diameter hole.
⚠
WARNING:
DO NOT mix parts from different systems unless stated in the manual.
NOTE:
It is critical to the proper and safe operation of this
fireplace that on all connections the inner liner and the
outer casing are both caulked with liberal amounts of
sealant. Do not use any kind of tape or silicone other than
that recommended in this manu
al. Use Mill Pac Sealant.
79
Summary of Contents for marquis ZCV39LPE2
Page 62: ...Gas Conversion for Modulator PART C 62...
Page 67: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 67...
Page 68: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 68...
Page 75: ...Proflame 2 Remote Control 75...
Page 77: ...77...