The light will stay on for the entire opening manoeuvre and for the 

subsequent  pause  time;  during  the  closing  manoeuvre  both  the 

green and red lights will be activated (the result being yellow) to indi-
cate there is no longer any transit priority (see table).

Table 1

Red

Green

Meaning

OFF

OFF

Bar closed, no passage in either direction

OFF

ON

Bar open, free transit

ON

OFF

Bar open, transit occupied

ON

ON

Bar closing and transit not controlled

The two Bar Open Indicator and Courtesy Light outputs can directly 
control small 24 V DC lamps for a total of 10 W. If stronger lamps have 
to be used, use the relays piloted by the unit outputs that control, in 

turn, the traffic lights.

IMPORTANT! - It is best to fit the radio receiver at this point, 

once all adjustments have been completed and with the pow-

er switched off.

3.7 - 

Description of the functioning  

modes

In the manual functioning mode the OPEN input allows movement 
up to the opening point; the CLOSE input allows movement up to 
the closing point; STEP-BY-STEP allows alternative opening and clos-
ing manoeuvres; as soon as the command in input stops, movement 
stops. In the opening phase movement stops when the maximum 
opening point is reached or if there is no consent from PHOTOCELL 
2; to the contrary, in the closing phase movement will stop at the max-
imum closed point or if there is no consent from the PHOTOCELL. If 
STOP is triggered it will cause movement to stop immediately both in 
the opening and closing manoeuvres. Once movement has stopped 
the command in input has to be stopped before any new movements 
can be active)
In either of the automatic functioning modes (semiautomatic-auto-
matic and closes always) a command on the OPEN input will cause 
an opening manoeuvre; if the command remains (TIMER) once the 

bar is open, the bar remains “frozen” in an infinite pause; only when 

the command stops will the bar be able to close. Command pulses 
on the CLOSE input will cause a closing manoeuvre; if the command 
remains the bar will stay locked in the closed position until the com-
mand ceases and only then can it be reopened. A pulse on STEP-BY-
STEP causes alternative opening and closing.
A second pulse on the STEP-BY-STEP or on the same input that 
started the movement, will cause a Stop.

Whether in the opening or closing phase, if STOP triggers it will cause 
movement to stop immediately.
In an opening manoeuvre, triggering of the PHOTOCELL has no ef-
fect while PHOTOCELL 2 will cause reversal of movement; in a clos-
ing manoeuvre, triggering of the PHOTOCELL causes movement to 
reverse followed by a new pause and lastly reclosing. If at the begin-
ning of an opening movement, the PHOTOCELL input does not give 

consent, the request to open is cancelled.

If the automatic functioning mode is being used, there will be a pause 

time subsequent to an opening manoeuvre and followed by a closing 

manoeuvre. If, during the pause the PHOTOCELL triggers, the timer 
will be reset with a new time; if, on the other hand, a STOP comes 
into play during the pause, the reclosing function will be cancelled and 
there will be a STOP condition.

3.8 - 

Charge card also battery 

 

powered

The road boom gate is equipped with a power transformer that can 
withstand the energy required by both the motor and electronic card 

so it can all be powered directly by the mains.
If you want the system to work even when there is a power cut then 
you have to add a suitable battery and relative battery charger card.
The battery must be installed in its own compartment outside the 
plastic box that protects the gearmotor card and connected to two 
terminals on the battery charger card; the latter must be connected to 
the connector on the unit.

4. 

Technical featurs of the unit

Open4000 technical features

Mains power

230 V AC ± 10%, 50-60 Hz

Battery power

21-28 V DC (> 6Ah capacity)

Max. current accessories, 24 V DC

200 mA

Max. power flashing light

25 W [24 V DC]

Max. power Courtesy Light

10 W [24 V DC]

Max. power Open Bar indicator

10 W [24 V DC]

Pause time

from 3 to 120 seconds

Courtesy light time

60 seconds

Operating temperature

-20 to 70° C

Summary of Contents for STAR OPEN 4000

Page 1: ...l uso EN Automatic boom gate electronic installation Installation and use instructions and warnings FR Barri re automatique Installation lectronique Instructions et avertissements pour l installation...

Page 2: ......

Page 3: ...senso di rotazione corretto ripetendo l opera zione descritta sopra 08 Regolare provvisoriamente i trimmer STOP_AMPERE e FOR ZA LAVORO al massimo della corsa TEMPO PAUSA al minimo e FORZA RALLENTAMEN...

Page 4: ...rogetto di nuova concezione infatti l attuatore dispone di finecorsa con un sistema di controllo della velocit che permette il raggiungimento dei limiti di corsa attraverso una fase di rallentamen to...

Page 5: ...Chi esegue detti interventi si rende responsabile di eventuali danni causati 3 Collegamenti elettrici Di seguito una breve descrizione dei possibili collegamenti della cen trale verso l esterno 1 2 2...

Page 6: ...velocit ridotta per altri 3 secondi 12 Regolare i Trimmer FORZA LAVORO e FORZA RALLENTA MENTO per ottenere che la manovra avvenga con la velocit e la spinta desiderata e che la fase di rallentamento...

Page 7: ...oi dopo 5 secondi 2 sec se in manuale inizia il movimento Switch 6 On Lampeggiante anche in Pausa Normalmente il lampeggiante viene attivato solo durante il movimen to in apertura o chiusura questa fu...

Page 8: ...do sull ingresso CHIUDE provocano la chiusura se il comando permane l asta rimarr bloccata in chiusura fino al cessare del comando solo dopo potr essere riaperta Un impulso su PASSO P provoca alternat...

Page 9: ...en turned 180 c Unplug the LIMIT SWITCH connector and replug it after it has been turned 180 07 See if rotation direction is right repeating the procedure de scribed above 08 Temporarily adjust the ST...

Page 10: ...limits by means of a slowing down phase In addition the effort the motor is subject to during movement is promptly detected as well as any obstacles that may be in the path and in such an event direc...

Page 11: ...se jobs shall be held re sponsible for any damage caused 3 Electrical connections Here is a brief description of the possible connections on the unit to the outside 1 2 230 V AC 230 V AC 50 60 Hz powe...

Page 12: ...ought to continue for a further 3 seconds at a slower speed 12 Adjust trimmers WORKING FORCE and SLOWING DOWN FORCE so that the manoeuvre is carried out at the speed and with the force required and th...

Page 13: ...t starts Switches 6 On Flashing also in Pause The flashing light is normally activated only during the opening and closing manoeuvres with this function the flashing light remains ac tive also during...

Page 14: ...cause a closing manoeuvre if the command remains the bar will stay locked in the closed position until the com mand ceases and only then can it be reopened A pulse on STEP BY STEP causes alternative o...

Page 15: ...remettre tourn de 180 c Extraire le connecteur FIN DE COURSE et le remettre tourn de 180 07 Contr ler de nouveau si le sens de rotation est correct en r p tant l op ration d crite plus haut 08 R gler...

Page 16: ...c moteur en courant continu 24 V Il s agit d un projet de conception nouvelle car en effet l actionneur dispose de micro interrupteurs de fin de course avec un syst me de contr le de la vitesse qui pe...

Page 17: ...ct des normes UNI 8612 et suivant les meilleures indications dict es par les r gles de l art Qui effectue ces interventions se rend responsable des ventuels dom mages qui en d coulent 3 Branchements l...

Page 18: ...entr e en jeu du ralentissement qui permet la poursuite de la course une vitesse r duite pendant 3 secondes de plus 12 R gler les Trimmers FORCE TRAVAIL et FORCE RALENTIS SEMENT pour obtenir que la ma...

Page 19: ...r s 5 secondes 2 s en mode manuel le mouvement commence Dip switch 6 On Clignotement galement en Pause Normalement le clignotant est activ seulement durant le mouve ment en ouverture ou en fermeture c...

Page 20: ...erm e Les impul sions de commande sur l entr e FERMETURE provoquent la ferme ture si la commande persiste la barre restera bloqu e en fermeture jusqu la cessation de la commande ce n est qu apr s qu e...

Page 21: ...siguiente manera a Desconecte la alimentaci n el ctrica de la barrera b Extraiga el conector MOTOR e introd zcalo nuevamente girado 180 c Extraiga el conector FIN DE CARRERA e introd zcalo nue vamente...

Page 22: ...tope con un sistema de control de la velocidad que permite alcanzar los l mites de carrera a trav s de una etapa de ralentizaci n adem s se detecta el esfuerzo al cual est sometido el motor durante e...

Page 23: ...A continuaci n describimos brevemente las posibles conexiones de la central hacia el exterior 1 2 230 Vca Alimentaci n el ctrica 230 Vca 50 60 Hz 3 4 Intermitente Salida para la conexi n a la luz inte...

Page 24: ...ue permite que la carrera contin e por otros 3 segundos a una velocidad lenta 12 Regule los trimmers FUERZA TRABAJO e FUERZA RALENTI ZACI N para que la maniobra se produzca a la velocidad y empuje des...

Page 25: ...modalidad manual inicia el movimiento Switch 6 On Intermitente en Pausa Normalmente la luz intermitente se acciona s lo durante el movi miento de apertura o cierre esta funci n prev que la luz interm...

Page 26: ...uevamente Los impulsos de mando en la entrada CIERRA producen el cierre si el mando contin a la barrera quedar bloqueada en cierre hasta que el mando finalice y s lo despu s se podr abrir nuevamente U...

Page 27: ...Declaration in accordance with Directives 2004 108 EC EMC 2006 42 EC MD annex II part B Declaration number K106 OPEN Rev 0 Language EN Name of manufacturer KING GATES S r l Address Via Malignani 42 3...

Page 28: ...tails Dati del costruttore Manufacturer s details Timbro Stamp Azienda Company Localit Address Provincia Province Recapito telefonico Tel Referente Contact person King Gates S r l Phone 39 0434 737082...

Reviews: