10
※
SELECT (P+UP Enter into Menu) Sr Key
Function
Name
Set up Time
and Value
Description
Buzz Time/ Light
Factory default
settings
Sr
Y or N
OKALL display mode _Y: Small loop
;
N: Big loop
---
N
※Auto learning mode “Ln” (S+P Enter into Menu)
SL=SC=At=RC=SP=Ht=P Key
Function
Name
Set up Time
and Value
Description
Buzz Time/ Light
Factory default
settings
SL
U1~UU
Screw List
Select UP/DOWN to change value and
then press S to confirm.
U1
SC
0
~99
Counting number / count-down only
Select UP/DOWN to change value and
then press S to confirm.
05
At
0.0
~9.9
OKALL signal and time displayed.
Select UP/DOWN to change value and
then press S to confirm.
1.0
RC
0.0~9.9
Slow start time
Select UP/DOWN to change value and
then press S to confirm.
0.0
SP
L0~L9
Slow start RPM level L0:100%, L1~L9
(10
%
~90
%
)
Rated speed.
Select UP/DOWN to change value and
then press S to confirm.
L0
Ht
0.1~9.9
Ht time Stop time (Show wrong as screwdriver can’t sop at set time after
starting, can be used to test stripped screws)
A LED starts flashing as we entered
“0.0”. To return to normal working
status, needs to escape brake from
screwdriver and let screwdriver
automatic to record time of lock. And
then press P key to save it.
0.0
※LCD Keypad lock/ unlock function (S+UP)
Function
Name
Set up Time
and Value
Description
Buzz Time/ Light
Factory default
settings
LC
---
Keypad LOCK P/S/R button
---
---
UN
---
UNLOCK
---
---
※Alarm Settings (UP+DOWN)
Function
Name
Set up Time
and Value
Description
Buzz Time/ Light
Factory default
settings
ON
---
When OK, OKALL, or NG happens the alarm will be on to warn operators.
---
---
OFF
---
When NG happens the alarm will be on to warn operators.
---
---
FF
---
When OKALL or NG happens the alarm will be on to warn operators.
---
---
EF
---
When OK or OKALL happens the alarm will be on to warn operators.
---
---
※ Check Firmware & Hardware version (Press and hold DOWN key then press P key)
Name on category F/W version Description Remark Factory setting
Category
Version
Description
Remark
Factory Setting
CCD
board
F/W ver.
For example: When panel displays “1.0” the final display would be like
“1.000” if “00” comes after press P key. When panel displays “S0” by press
DOWN key the final display would be like “S000” if “00” comes after
press P key.
Hint:
There will have one digit come after
decimal when check CCD board, but
non on MCB board.
---
1.000
Special
Edition
MCB
board
F/W ver.
For example: When panel displays “1” the final display would be like
“1.00” if “00” comes after press P key. When panel displays “S0” by press
DOWN key the final display would be like “S000” if “00” comes after
press P key.
---
1.00
Special
Edition
S000
Disable Counter: Press and hold P key for 5 seconds until all digits were disappeared in the meantime, a LED light is on green.
You may return counter function back to original setting by pressing P key for 3 seconds during counter has been accessing.
Press R key to allow system returning to the factory setting.