background image

                   

                                                                                                                                                                                                   

 

 
 
 
 

Attaching / detaching bit and bit type   
Push up the holder clamp by finger tip, and it will be unlocked. Thus, the bit can be freely attached and detached (single finger 
notion type) select such a bit whose shank is equal to the size shown below.         
 
 

 Insert the power plug into a receptacle and set the changeover switch to “

F

 

position. 

 Apply the bit to the screw head and press the lever or push main body to, then the switch will be turned ON to start the motor 

running. 

 When the screw is 

tightened

 and reach the torque that you had set, 

the

 tool will

 be 

stopped automatically. 

 To reset the tool by releasing the lever to the original position or releasing the bit 

from

 the screw head.   

 To return the screw, set the changeover switch to “

R

” position. 

 
 
 
 
 

 

 

 

 

Maintenance and Inspection: 

1.

 

The screw driver must be operated in top condition, one day working hour must be not more than eight hours. 

  cording to operating frequency and torque loaded, we suggest adding lubricating oils in clutch per 3-6 months,   
  and kindly contact with distributor when product's maintenance . 

2.

 

Please note don’t let the motor get over heated, every minute use 10~15 screws to operate.     

3.

 

The frequency use of this electric screw driver is over than  eight hours a day, still it needs periodically testing and treatment. 
Every 5-6 months. 

4.

 

Inspect  tool  cords  periodically  and  if  damaged,  have  them  repaired  by  an  authorized  service  facility.  Inspect  extension  cords 
periodically and replace if damaged. 

5.

 

Do not remove any labels. Replace any damaged label. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

              Description of Operation   

                                  Servicing 

Summary of Contents for SKD-BE203L

Page 1: ...203LS6 SKD BE203LS7 SKD BE210P DC TYPE Automatic Non Carbon Brush with Counter Series KILEWS INDUSTRIAL CO LTD http www kilews com Y2F141Q 4E 001 Ver 4 0 Please scan the following QR code or download...

Page 2: ...on enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manu...

Page 3: ...equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when...

Page 4: ...ir person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provide a Instruction for putting into use 1 Setting u...

Page 5: ...and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm To...

Page 6: ...10 3 Function Key button For setting and control Please refer to Page 8 10 4 Forward Reverse Switch To switch screwdriver run in Reserve or Forward R Run in reserve to untighten screw F Run in Froward...

Page 7: ...w head To return the screw set the changeover switch to R position Maintenance and Inspection 1 The screw driver must be operated in top condition one day working hour must be not more than eight hour...

Page 8: ...center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nea...

Page 9: ...umption 25W Torque kgf cm 0 2 3 5 0 5 7 1 10 0 2 3 5 0 2 3 5 0 2 3 5 2 10 Lbf in 0 18 3 01 0 44 6 10 0 89 8 67 0 18 3 01 0 18 3 01 0 18 3 01 1 77 8 67 N m 0 02 0 34 0 05 0 69 0 10 0 98 0 02 0 34 0 02...

Page 10: ...L9 Slow start RPM level L0 100 L1 L9 10 90 Rated speed L0 Ht 0 1 9 9 Ht time Stop time Show wrong as screwdriver can t sop at set time after starting can be used to test stripped screws Without releas...

Page 11: ...ypad LOCK P S R button UN UNLOCK Alarm Settings UP DOWN Function Name Set up Time and Value Description Buzz Time Light Factory default settings ON When OK OKALL or NG happens the alarm will be on to...

Page 12: ...hange number and then push S confirm 3 Show At automatic zero UP DOWN to change value then push P confirm 4 Enter simulate learning LED 1 will keep flash 5 When recording value push P key and back wor...

Page 13: ...g time If three seconds are set but no starting signal after set time it will buzz Push R key to restore to factory settings General execution of pre set program Start LL 1 5 Lt 1 00 If stop is among...

Page 14: ...orque checker measures the torque of screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque c...