9
No
Name
Function
1
Three-Color
Light
To Show operating is OK, N.G or in the mode condition.
2
Panel
To show set value, set screws number and other value
3
Power Switch
Push five seconds: to disable COUNTING FUNCTION
CLEAR Push three seconds: CLEAR
4
SELECT Key
Push three seconds: Enter the system
5
Up Key
When entering the system , this key increases value
6
Down Key
When entering the system , this key decreases value
This key is symbolized to reduce numbers when press it on setting
menu from system. This key also will become numbering of tasks
if it works under working page.
7
Reset
Restore to factory settings
※
S+P
Automatic learning.
※
UP+P
Set OKALL display mode, external fixture GATE & open/
short start mode.
※
UP+DOWN
Buzzer mode
※
S+UP
If press together to enable P/R/S button, and then press again to
disable P/R/S button.
※Push three seconds to enter the selection) SL==SC==At==RC==SP==Ht==Lt==LL==Ns==Rn==Rt <Confirm>
Function
Name
Set up Time
and Value
Description
Buzz Time/ Light
Factory default
settings
SL
01-UU
Screw List
;
Screw List (The tightening process will not count if SC sets as 0
at U1 and screws displayed as 00)
An U1 is the first data set, an U2 is the
second data set, and on to UU as cycle.
To stop counting in cycle mode, let SC
to become 0 to end of cycle. For
example, sets SC as 0 at U3, and then
sets UU to become cycle mode. The
tightening would act cycling between
U1 and U2.
U1
SC
0-99
Counting number / count-down only
;
The tightening process will not count
if SC sets as 0 at U1 and screws displayed as 00.
not cycle count if SC sets as 0 at U1
05
At
0.0-9.9
OKALL Signal output time
---
1.0
RC
0.0~9.9
Slow start time
When RC=0 or SP=L0 the slow start
function could not work.
0.0
SP
L0~L9
Slow start RPM level L0:100%, L1~L9
(10
%
~90
%
)
Rated speed.
L0
Ht
0.1-9.9
Ht time Stop time (Show wrong as screwdriver can’t sop at set time after
starting, can be used to test stripped screws)
Without release trigger from screwdriver
the buzz is on continuously and red LED
keeps flashing.
2.0
Lt
0.01-9.9
(1) Lo time
;
An ERROR happens when the time of screwdriver stopped
working from started less than the time has set in Lt setting.
(2) “02.” is displayed as 0.02. To make a change by press P key for
adjusting decimal point. It can be modified as 0.2.
(3) The Lt value could not greater than Ht during setting. So, the system
will change Lt in 0.1 lass than Ht. automatically.
Three buzz and LED red flash
0.00
LL
0.01-9.9
Reconfirm time after fastening.
(1) Reconfirm setting time after fastening.
(2) “02.” is displayed as 0.02. To make a change by press P key for
adjusting decimal point. It can be modified as 0.2.
(3) There will output an OK signal after time up in LL, and green LED will be
on.
Rt & LL setting values could not
coexist. So, either make Rt or LL setting
alone only.
0.00
Ns
Y or N
Ns
:
Set the function of stopping the screwdriver when any error message
occurs.
Y: Stop the screwdriver when any error occurred meanwhile, Reverse is
OK; Restore by pressing “S” button Forward locking.
N: screwdriver could operate continually when any error occurred.
LCD displays NS”
NsHt: 4 beeps
NsLt: 3 beeps
Red LED is always on
N
Rn
Y or N
Rn
:
Set the count-up mode for the reversion.
Y:taken in count for each reversion
;
N:Only count once when reverse
﹐
OF:
Reversing but no counting down.
---
N
Rt
0.01 – 9.99
(1) Rt
:
Set auto reverse time after the screwdriver shutting off.
(2) “02.” is displayed as 0.02. To make a change by press P key for
adjusting decimal point. It can be modified as 0.2.
Rt & LL setting values could not
coexist. So, either make Rt or LL setting
alone only.
0.00