background image

                   

                                                                                                                                                                                                   

 

 
 
 
 

1) Whenever changing a bit, make certain the Forward / Reverse Switch is in the “OFF “position and tool is unplugged. 
2) Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or other similar chemicals to 

  come in contact with the screwdriver housing as damage will result.   

3) Do not drop or abuse the screwdriver. 
4) Do not adjust the torque setting higher than 8 on the torque scale. 
5) There should be a tool rest interval when cycles three seconds or longer. This tool is intended for a duty cycle of 1.0 sec on, 3.0 

sec off. 

 
 
 
 
 

6) Do not use this screwdriver for tightening wood screws. This is “Metal Assembly Screw Driver” 
7) Do not operate the Forward / Reverse Switch the motor is running. 
8) Whenever a tool is not being used, move the Forward / Reverse Switch to the “OFF” position and unplug the screwdriver. 
9) Don't touch For&Rew Switch during operating for keeping system from wrong judgment. 

 
 
 
 

● Do not drop or abuse the tool.   
● Whenever a tool is not being used, position the Power Switch to the “OFF” position and unplug the power cord. 

 

 
 

 

(1). LED Light : Indicate OK/NG

 

(2). LED Display : Counting or Setting Value Display , Please refer to Page 8~10

 

(3). Function Key button : For setting and control, Please refer to Page 8~10

 

(4). Forward/Reverse Switch : To switch screwdriver run in Reserve or Forward   
          R : Run in reserve to untighten screw

 

          F : Run in Froward to tighten screw

 

(5). Level switch : Press and hold to start screwdriver, release to stop

 

(6). Front Locking Ring : To fixed the housing of screwdriver

 

(7). Torque Adjusting Ring : To adjust torque from low   

(scale 0) to high (scale 8) torque

 

(8). Bit holder cap : Pull out to put bit into the holder   

or take out from the holder

 

 
 
 

 
 
 
 
 
 

 

Slow speed (rpm)  operation frequency  Slow speed (rpm)  operation frequency  Slow speed (rpm)  operation frequency 

900 

1.0 ON 3.0 OFF 

600 

1.0 ON 3.0 OFF 

300 

2.0 ON 5.0 OFF 

850 

1.0 ON 3.0 OFF 

550 

2.0 ON 5.0 OFF 

250 

2.0 ON 5.0 OFF 

800 

1.0 ON 3.0 OFF 

500 

2.0 ON 5.0 OFF 

200 

2.0 ON 5.0 OFF 

750 

1.0 ON 3.0 OFF 

450 

2.0 ON 5.0 OFF 

150 

2.0 ON 5.0 OFF 

700 

1.0 ON 3.0 OFF 

400 

2.0 ON 5.0 OFF 

100 

2.0 ON 5.0 OFF 

650 

1.0 ON 3.0 OFF 

350 

2.0 ON 5.0 OFF 

 

 

                    Operations Cautions 

CAUTION 

                    Function Discription 

 

Slow speed Duty Cycle Conversion (for reference) 
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650

 

650/1000%=65% 
ON= 1*1.65= 1.65

OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF 

This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off. 

(5) 

Under Pressure 

L-TYPE

 

P-TYPE

 

(1) 

(5) 

(2) 

(3) 

(4) 

(6) 

(7) 

(8) 

(1) 

(2) 

(3) 

(4) 

(6) 

(7) 

(8) 

Summary of Contents for SKD-BE203L

Page 1: ...203LS6 SKD BE203LS7 SKD BE210P DC TYPE Automatic Non Carbon Brush with Counter Series KILEWS INDUSTRIAL CO LTD http www kilews com Y2F141Q 4E 001 Ver 4 0 Please scan the following QR code or download...

Page 2: ...on enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manu...

Page 3: ...equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when...

Page 4: ...ir person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provide a Instruction for putting into use 1 Setting u...

Page 5: ...and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm To...

Page 6: ...10 3 Function Key button For setting and control Please refer to Page 8 10 4 Forward Reverse Switch To switch screwdriver run in Reserve or Forward R Run in reserve to untighten screw F Run in Froward...

Page 7: ...w head To return the screw set the changeover switch to R position Maintenance and Inspection 1 The screw driver must be operated in top condition one day working hour must be not more than eight hour...

Page 8: ...center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nea...

Page 9: ...umption 25W Torque kgf cm 0 2 3 5 0 5 7 1 10 0 2 3 5 0 2 3 5 0 2 3 5 2 10 Lbf in 0 18 3 01 0 44 6 10 0 89 8 67 0 18 3 01 0 18 3 01 0 18 3 01 1 77 8 67 N m 0 02 0 34 0 05 0 69 0 10 0 98 0 02 0 34 0 02...

Page 10: ...L9 Slow start RPM level L0 100 L1 L9 10 90 Rated speed L0 Ht 0 1 9 9 Ht time Stop time Show wrong as screwdriver can t sop at set time after starting can be used to test stripped screws Without releas...

Page 11: ...ypad LOCK P S R button UN UNLOCK Alarm Settings UP DOWN Function Name Set up Time and Value Description Buzz Time Light Factory default settings ON When OK OKALL or NG happens the alarm will be on to...

Page 12: ...hange number and then push S confirm 3 Show At automatic zero UP DOWN to change value then push P confirm 4 Enter simulate learning LED 1 will keep flash 5 When recording value push P key and back wor...

Page 13: ...g time If three seconds are set but no starting signal after set time it will buzz Push R key to restore to factory settings General execution of pre set program Start LL 1 5 Lt 1 00 If stop is among...

Page 14: ...orque checker measures the torque of screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque c...

Reviews: