Step 4 -Install the Modules
M8920A Getting Started Guide
47
Item
Description
Remarks
#
Port Name
1
Status LED
LED indicator of the
module status
Green: Modular TRX is running normally.
Red: Modular TRX has been invoked with error,
error message has been logged into the event
viewer.
Blink: FPGA is updating on the module.
Off: The module is not in above situations.
2
RF Output
RF output port
Output Level: –130 dBm to 0 dBm
Connects to the RF input port of the M9470A 50 W
Interface module via a rigid cable.
Refer to
M8920A Block Diagram (page 45)
3
Trigger 2
Source trigger port
Trigger source output, 3.3 V into 50 Ω
This trigger is available for the M8920A.
4
Trigger 1
Source trigger port
External trigger input:
Sine or square wave –2 V to +5 V max into 50 Ω,
+16 dBm max at 0 VDC into 50 Ω
This trigger is available for the M8920A.
5
RFIO HD
Half duplex port for
RF input or
RF output
This port is not available to the M8920A.
6
RF Input
RF input port
Received input:
Maximum input power: 27 dBm
Connects to the RF output of the M9470A 50 W
Interface module via a rigid cable.
Refer to
M8920A Block Diagram (page 45)
7
Trigger 4
Received trigger
port
Trigger received output,
3.3 V into 50 Ω
This trigger is available for the M8920A.
8
Trigger 3
Receiver trigger
port
External trigger output:
Sine or square wave –2 V to +5 V max into 50 Ω,
+16 dBm max at 0 VDC into 50 Ω
This trigger is available for the M8920A.
9
100 MHz In
100 MHz reference
input
This SMB male connectorW receives the 100 MHz
reference signal from the M9470A 50 W Interface
module via a rigid cable. Refer to
Summary of Contents for M8920A
Page 1: ...Getting Started Guide Keysight M8920A PXIe Radio Test Set...
Page 8: ...viii...
Page 38: ...38 M8920A Getting Started Guide...
Page 66: ...66 M8920A Getting Started Guide...
Page 74: ...74 M8920A Getting Started Guide...
Page 78: ...78 M8920A Getting Started Guide...
Page 86: ...86 M8920A Getting Started Guide...
Page 89: ...Cable and Connector Care M8920A Getting Started Guide 89 Male connector...