The following detailed instructions are for connecting an OML T/R module.
These instructions assume a cable dress kit (black sleeving) is available. Modify
the instructions appropriately for other types of modules.
1.
Prepare the cable bundle comprised of five cables listed in
a.
Complete Steps 1 through 5 of the Installation Guide from the
Millimeter-wave Cable Dress Kit (document number N5260-90070
contained in kit part number N5261-60019). DO NOT APPLY THE
VELCRO ASSEMBLIES AT THIS TIME.
2.
Connect the five cables to the front panel of the controller in the following
order. Use two right angle adapters (1260-2604).
Figure 1-25
Controller Front Panel Connections
3.
Repeat
for each module in the system.
Table 1-13
Controller Connections
Order
Test Set
Module (OML)
1
DC POWER
+12 V
2
TEST IF
Test I.F.
3
REF IF
Ref I.F.
4
RF OUT
R.F. In
5
LO OUT
L.O. In
Summary of Contents for N5261A