background image

2

Keysight M9260A Startup Guide

Notices

Copyright Notice

© Keysight Technologies 2017 - 2018
No part of this manual may be repro-

duced in any form or by any means 

(including electronic storage and 

retrieval or translation into a foreign 

language) without prior agreement and 

written consent from Keysight Technol-

ogies as governed by United States and 

international copyright laws.

Manual Part Number

M9260-90000

Edition

Edition 3, May 2018

Printed in:

Printed in Malaysia

Published by:

Keysight Technologies

Bayan Lepas Free Industrial Zone,

11900 Penang, Malaysia

Technology Licenses 

The hardware and/or software 

described in this document are fur-

nished under a license and may be 

used or copied only in accordance with 

the terms of such license.

Declaration of Conformity

Declarations of Conformity for this 

product and for other Keysight prod-

ucts may be downloaded from the 

Web. Go to 

http://www.keysight.com/

go/conformity

. You can then search by 

product number to find the latest Dec-

laration of Conformity.

U.S. Government Rights

The Software is “commercial computer 

software,” as defined by Federal Acqui-

sition Regulation (“FAR”) 2.101. Pursu-

ant to FAR 12.212 and 27.405-3 and 

Department of Defense FAR Supple-

ment (“DFARS”) 227.7202, the U.S. 

government acquires commercial com-

puter software under the same terms 

by which the software is customarily 

provided to the public. Accordingly, 

Keysight provides the Software to U.S. 

government customers under its stan-

dard commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of which can 

be found at 

http://www.keysight.com/

find/sweula

. The license set forth in the 

EULA represents the exclusive authority 

by which the U.S. government may use, 

modify, distribute, or disclose the Soft-

ware. The EULA and the license set 

forth therein, does not require or per-

mit, among other things, that Keysight: 

(1) Furnish technical information 

related to commercial computer soft-

ware or commercial computer software 

documentation that is not customarily 

provided to the public; or (2) Relinquish 

to, or otherwise provide, the govern-

ment rights in excess of these rights 

customarily provided to the public to 

use, modify, reproduce, release, per-

form, display, or disclose commercial 

computer software or commercial com-

puter software documentation. No 

additional government requirements 

beyond those set forth in the EULA 

shall apply, except to the extent that 

those terms, rights, or licenses are 

explicitly required from all providers of 

commercial computer software pursu-

ant to the FAR and the DFARS and are 

set forth specifically in writing else-

where in the EULA. Keysight shall be 

under no obligation to update, revise or 

otherwise modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant to FAR 

12.211 and 27.404.2 and DFARS 

227.7102, the U.S. government 

acquires no greater than Limited Rights 

as defined in FAR 27.401 or DFAR 

227.7103-5 (c), as applicable in any 

technical data.

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO THE 

MAXIMUM EXTENT PERMITTED BY 

APPLICABLE LAW, KEYSIGHT DIS-

CLAIMS ALL WARRANTIES, EITHER 

EXPRESS OR IMPLIED, WITH REGARD 

TO THIS MANUAL AND ANY INFORMA-

TION CONTAINED HEREIN, INCLUD-

ING BUT NOT LIMITED TO THE 

IMPLIED WARRANTIES OF MER-

CHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE. KEYSIGHT 

SHALL NOT BE LIABLE FOR ERRORS 

OR FOR INCIDENTAL OR CONSE-

QUENTIAL DAMAGES IN CONNECTION 

WITH THE FURNISHING, USE, OR 

PERFORMANCE OF THIS DOCUMENT 

OR OF ANY INFORMATION CON-

TAINED HEREIN. SHOULD KEYSIGHT 

AND THE USER HAVE A SEPARATE 

WRITTEN AGREEMENT WITH WAR-

RANTY TERMS COVERING THE MATE-

RIAL IN THIS DOCUMENT THAT 

CONFLICT WITH THESE TERMS, THE 

WARRANTY TERMS IN THE SEPARATE 

AGREEMENT SHALL CONTROL.

Safety Information

CAUTION

A CAUTION notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in damage to the product 

or loss of important data. Do not pro-

ceed beyond a CAUTION notice until 

the indicated conditions are fully 

understood and met.

WARNING

A WARNING notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in personal injury or death. 

Do not proceed beyond a WARNING 

notice until the indicated conditions are 

fully understood and met.

Summary of Contents for M9260A

Page 1: ...Keysight M9260A PXIe Audio Analyzer Startup Guide...

Page 2: ...tomarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No additional government requir...

Page 3: ...re to comply with these requirements Caution risk of danger refer to this manual for specific Warning or Caution information WARNING If this product is not used as specified the protection provided by...

Page 4: ...that are not safety related may be purchased from other suppliers as long as they are equivalent to the original component note that selected parts should be purchased only through Keysight to mainta...

Page 5: ...below shows the general environmental requirements for this instrument Environmental condition Requirement Temperature Operating condition 0 C to 55 C Storage condition 40 C to 71 C Humidity Operatin...

Page 6: ...61326 1 EN 61326 1 Immunity for industrial electromagnetic environment Canada ICES NMB 001 Issue 4 June 2006 Australia New Zealand AS NZS CISPR 11 Supplementary information The product was tested in a...

Page 7: ...This equipment has been conformity assessed for use in business environments In a residential environment this equipment may cause radio interference This EMC statement applies to the equipment only...

Page 8: ...es with the Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada ISM GRP 1 Class A indicates that this is an Industrial Scientific and Medical Group 1 Class A product The RCM m...

Page 9: ...nitoring and Control Instrument product The affixed product label is as shown below Do not dispose in domestic household waste To return this unwanted instrument contact your nearest Keysight Service...

Page 10: ...10 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 11: ...lation and Verification Introduction 18 Related documentation 18 Step 1 Unpack and Inspect the Module 19 ESD precaution 19 Inspect the module for damage 21 Return the module for service 22 Step 2 Veri...

Page 12: ...12 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 13: ...cedures 31 Figure 1 5 M9260A PXIe Audio Analyzer front panel 32 Figure 1 6 M9260A functional block diagram 33 Figure 1 7 M9260A SFP interface 34 Figure 1 8 Connecting the BNC BNC cables from the gener...

Page 14: ...14 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 15: ...Keysight M9260A Startup Guide 15 List of Tables Table 1 1 System requirements 24 Table 1 2 Configuration for M9260A audio analyzer 37 Table 1 3 Operational verification table 40...

Page 16: ...16 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 17: ...8 Step 1 Unpack and Inspect the Module 19 Step 2 Verify the Shipment Contents 23 Step 3 Install the Controller and Software 24 Step 4 Install the Module 28 Step 5 Verify the Operation of the M9260A Mo...

Page 18: ...sight com find M9260A Related documentation The Keysight M9260A PXIe Audio Analyzer documentation listed below can be downloaded for free through our website at http www keysight com find M9260A You c...

Page 19: ...icant level of ESD protection Of the two only the table mat with wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provide...

Page 20: ...ication 20 Keysight M9260A Startup Guide Figure 1 1 Example of a static safe work station WARNING These techniques for a static safe work station should not be used when working on circuitry with a vo...

Page 21: ...arefully inspect the unit for any shipping damage Report any damage to the shipping agent immediately as such damage is not covered by the warranty The warranty also does not cover Damage from contami...

Page 22: ...tag and attach it to the defective M9260A Name and address of owner A P O box is not acceptable as a return address Product model number for example M9260A Product serial number for example MYXXXXXXX...

Page 23: ...uide 23 Step 2 Verify the Shipment Contents The following items are included in the M9260A shipment M9260A PXIe Audio Analyzer module Certificate of Calibration NOTE All software and product informati...

Page 24: ...um 64 is not supported Available memory 2 GB minimum Available hard disk space a 2 GB available hard disk space Display Resolution 1024 768 Input Device Mouse or a compatible pointing device Browser M...

Page 25: ...nstall the PCIe adapter drivers The following steps describe setting up the embedded controller 1 Install the embedded controller module into a compatible PXIe chassis 2 Connect your I O peripherals m...

Page 26: ...the following Keysight IO Libraries Suite IOLS which includes the Keysight Connection Expert Soft Front Panel SFP device drivers IVI C IVI COM LabVIEW G and related user documentation for the M9260A 1...

Page 27: ...Inspection Installation and Verification 1 Keysight M9260A Startup Guide 27 Figure 1 2 InstallShield Wizard for Keysight M9260A 3 Once installation is complete power down the PC and the PXIe chassis...

Page 28: ...g Refer to the chassis documentation for more information about cooling CAUTION The PXIe hardware does not support hot swapping capabilities changing modules while power is applied to the chassis Befo...

Page 29: ...d bottom Slide the module to the rear of the chassis and ensure that the injector ejector handle is pushed down in the unlatched downward position Slide the module completely into the chassis When you...

Page 30: ...irflow 8 Install all chassis covers and filler panels after installing the module Missing filler panels may disrupt necessary air circulation in the chassis 9 Plug in the power cable and power up the...

Page 31: ...llation procedures Module installation procedures 1 Press down the ejector 2 Slide the M9260A module into any slot until the backplane connectors touch 3 Seat the M9260A module into the chassis by pul...

Page 32: ...1 Inspection Installation and Verification 32 Keysight M9260A Startup Guide M9260A front panel Figure 1 5 M9260A PXIe Audio Analyzer front panel...

Page 33: ...Inspection Installation and Verification 1 Keysight M9260A Startup Guide 33 M9260A audio analyzer functional block diagram Figure 1 6 M9260A functional block diagram...

Page 34: ...FP software included with this product Launch the M9260A SFP by clicking its desktop shortcut icon or by clicking Start All Programs Keysight M9260 PXIe Module M9260 SFP Windows 7 The M9260 SFP module...

Page 35: ...ves measuring the Vac Frequency THD N and THD parameters The average value from the measured data samples will then be calculated The measurement results average are then compared to the known values...

Page 36: ...on 36 Keysight M9260A Startup Guide Figure 1 8 Connecting the BNC BNC cables from the generator outputs to the analyzer inputs 3 Configure the M9260A PXIe Audio Analyzer using the SFP based on the set...

Page 37: ...dance 50 Output Differential Waveform Sine Amplitude 1 Vp Frequency 1 kHz DC Offset 0 V Analog Analyzer Channels 1 2 Configure one channel at a time Range 1 Vp Connection BNC Input Differential Impeda...

Page 38: ...1 Inspection Installation and Verification 38 Keysight M9260A Startup Guide Figure 1 9 Configuring the Analog Generator Figure 1 10 Configuring the Analog Analyzer...

Page 39: ...ing Generator Off so that it becomes Generator On 5 On the Acquire section select Continuous to initiate the audio analyzer to acquire data and perform the measurement The results will be displayed un...

Page 40: ...ues Table 1 3 Operational verification table Output Amplitude Input Range Measurement Low Limit High Limit 0 316 V 0 32 V Vac 0 2123 V 0 2346 V Freq 999 998 Hz 1000 02 Hz THD N 103 dB THD 110 dB 1 V 1...

Page 41: ...of range refer to Return the module for service on page 22 for details on sending the module back to Keysight Technologies for service 10 V 46 V Freq 999 998 Hz 1000 02 Hz THD N 90 dB THD 105 dB Table...

Page 42: ...1 Inspection Installation and Verification 42 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 43: ...Analyzer Startup Guide 43 2 Characteristics and Specifications For the characteristics and specifications of the M9260A PXIe Audio Analyzer refer to the datasheet at http literature cdn keysight com...

Page 44: ...2 Characteristics and Specifications 44 Keysight M9260A Startup Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 45: ...ion is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2017 2018 Edition 3 May 2018 Printed in Malaysia M9260 90000 M9260 90000 www...

Reviews: