background image

 4

 

 

Notices

The information contained in this document is subject to change without notice.

This document contains proprietary information that is protected by copyright. All 
rights are reserved. No part of this document may be photocopied, reproduced, or 
translated to another language without the prior written consent of the Keysight 
Technologies.

Keysight Technologies Japan, Ltd.

Component Test PGU-Kobe

1-3-3 Higashikawasaki-cho, Chuo-Ku Kobe-shi, Hyogo, 650-0044 Japan

© Copyright  Keysight Technologies Japan, Ltd. 1999, 2001, 2015

Manual Printing History

The manual’s printing date and part number indicate its current edition. The 
printing date changes when a new edition is printed. (Minor corrections and 
updates incorporated in reprints do not necessitate a new printing date.) The 
manual part number changes when extensive technical changes are incorporated.

January 1999 

Edition 1 (part number: 16034-90001)

April 1999 

Edition 2 (part number: 16034-90011)

December 1999  Edition 3 (part number: 16034-90011)

January 2001 

Edition 4 (part number: 16034-90011)

March 2015

Edition 5 (part number: 16034-90011)

November 2016  Edition 6 (part number: 16034-90011)

Safety Summary

The following general safety precautions must be observed during all phases of 
operation, service, and repair of this instrument. Failure to comply with these 
precautions or with specific WARNINGS elsewhere in this manual may impair the 
protection provided by the equipment. Such noncompliance would also violate 
safety standards of design, manufacture, and intended use of the instrument.

Keysight Technologies assumes no liability for the customer’s failure to comply 
with these requirements.

Summary of Contents for 16034G

Page 1: ...Keysight 16034G Test Fixture Operation Manual...

Page 2: ......

Page 3: ...3...

Page 4: ...in reprints do not necessitate a new printing date The manual part number changes when extensive technical changes are incorporated January 1999 Edition 1 part number 16034 90001 April 1999 Edition 2...

Page 5: ...DO NOT substitute parts or modify instrument To avoid the danger of introducing additional hazards do not install substitute parts or perform unauthorized modifications to the instrument Return the i...

Page 6: ...rrants that its software and firmware designated by Keysight Technologies for use with an instrument will execute its programming instruction when property installed on that instrument Keysight Techno...

Page 7: ...upply Off Supply In position of push button switch Out position of push button switch Frame or chassis terminal A connection to the frame chassis of the equipment which normally includes all exposed m...

Page 8: ...8...

Page 9: ...ng the 16034G 16 Performing Short Correction 17 Performing Open Correction 18 DUT Measurement 19 DUT measurement over 3 MHz 20 3 Specifications and Supplemental Performance Characteristics Specificati...

Page 10: ...10 Contents...

Page 11: ...1 Overview...

Page 12: ...erview Product Overview Product Overview The 16034G is designed for chip type components whose sizes range from 0201 to 1306 This test fixture can take measurements of the chip type L C R Figure 1 1 P...

Page 13: ...shipment should be as listed in Table 1 1 If the contents are incomplete if there is mechanical damage or defect notify the nearest Keysight Technologies office If the shipping container is damaged or...

Page 14: ...nstrument s LCUR LPOT and HIGH side Contact Pin connected to a instrument s HCUR HPOT 2 Knob For lateral adjustment of HIGH side Contact Pin 3 Contact Pin Locking Screw For securing HIGH side Contact...

Page 15: ...2 Operation This chapter describes the proper methods for open and short correction and DUT measurement...

Page 16: ...e shows correction and measurement by the 16034G Connecting the 16034G 1 Set the cable length to 0 m in the instrument 2 Connect the 16034G directly to the UNKNOWN terminals as shown in Figure 2 1 Fig...

Page 17: ...llows 1 Push the HIGH side contact pin s knob to the left to make firm contact with the LOW side contact pin Figure 2 2 Tighten the contact pin locking screw to secure the HIGH side contact pin Figure...

Page 18: ...recommended that you place the DUT on the measuring stage and precisely position the HIGH side contact pin to actual DUT width 2 Tighten the contact pin locking screw to secure the HIGH side contact...

Page 19: ...of the measuring stage and secure the contact pin with the contact pin locking screw 2 Release the LOW side contact pin with the lever and set the DUT on the measuring stage 3 Ease back slowly on the...

Page 20: ...DUT measurement and perform measurement at 3 MHz to determine the value of the 100 SMD resistor 2 Set the measured resistance and inductance values to the instrument as load value 3 Perform load corre...

Page 21: ...3 Specifications and Supplemental Performance Characteristics This chapter provides specifications and supplemental performance characteristics of the 16034G test fixture...

Page 22: ...nalyzers with four terminals Applicable DUT Type Chip components Applicable DUT dimensions Maximum Voltage 40 V peak max AC DC Operating Environment temp 0 C to 55 C humidity 15 to 95 RH wet bulb temp...

Page 23: ...ORT correction Additional errors are calculated as follows Z Measurement Additional error Ze of the Z measurement is calculated by substituting the values in the table below into the following equatio...

Page 24: ...l error Rse of the Rs measurement is calculated by additional error Ze of Z measurement as follows If Dx 0 1 Rse Ze Dx If 0 1 Dx 0 5 Rse Ze Dx Dx is the measured value of D and is calculated as follow...

Page 25: ...ics Supplemental Performance Characteristics Contact Pressure The following data are supplemental performance characteristics for the spring that applies contact pressure Spring constant 37 gf mm 10 S...

Page 26: ...26 Chapter 3 Specifications and Supplemental Performance Characteristics Supplemental Performance Characteristics...

Page 27: ...This information is subject to change without notice Keysight Technologies 1999 2001 2015 2016 Edition 6 November 2016 16034 90011 16034 90011 www keysight com...

Reviews: