22
Cleaning mechanism retraction time
- this parameter is available only when the
cleaning mechanism is activated (AUTO mode, or CYCLE). It specifies the time
required for the mechanism retraction to the rest position after turning off the control
output.
M E C H A N I S M R E T U R N
T I M E
1 2 0 s
Cleaning mechanism pause time
- this parameter is available only when the
cleaning mechanism operates in CYCLE time. It specifies the time interval between
successive repetition of the cleaning cycle.
M E C H A N I S M P A U S E
T I M E
1 2 0 s
Number shut downs before cleaning
- this parameter is available only when the
cleaning mechanism operates in AUTO mode. Specifies which in turn start an
extinction cleaning procedure.
E X T I N C T I O N C O U N T
B E F O R E C L E A N
5
Minimum operating time without cleaning
- this parameter is available only when
the cleaning mechanism operates in AUTO mode. Specifies the minimum number of
hours the burner must in order to start cleaning. If the minimum time is not reached,
the cleaning will not run even if there was a required number of shut downs. Setting
the parameter to „0h" control the minimum time off work without cleaning.
M I N W O R K W I T H O U T
C L E A N I N G
2 h
The maximum working time without cleaning
- this parameter is available only
when the cleaning mechanism operates in AUTO mode. Specifies how many hours
the burner can work without cleaning. If the maximum time is reached, the cleaning
will run even if there was no required number of shut downs.
M A X
E O R K W I T H O U T
C L E A N I N G
1 2 h
5.5. Central heating pump work parameters.
Central heating pump switching on parameters
- this parameter specifies the
method of central heating pump switching on. Selection of „THERMOSTAT” setting
means that central heating pump will be switched on only if room thermostat
contacts are closed and in case of emergency (e.g. boiler overheating). Selection of
„AUTO” setting means that central heating pump operation will follow regardless of
room thermostat.