Stoker pause time
- this parameter specifies pause time during stoker operation
when in work cycle. This setting is unavailable if the stoker is switched off or in
automatic mode.
S T O K E R P A U S E
T I M E
3 s
Stoker extra work time
- this parameter is available only, when the stoker works in
automatic mode and it specifies stoker work time after auger switching off.
S T O K E R E X T R A
W O R K
T I M E
2 0 s
Stoker emptying time
– this parameter specifies time needed for removal of the
whole fuel from the stoker. Stoker emptying during extinguishing of feeder, feeding
initial fuel dose (portion), and during burner shut down. This setting is unavailable if
the stoker is switched off.
S T O K E R E M P T Y I N G
T I M E
4 0 s
Auger ignition test
- this parameter provides functionalities of „X” emergency input.
If „NO” setting was selected then „X” input will be used for connection of e.g. auger
flap opening contact sensor or the contact informing on operation of auger motor
overload switch. If „YES” setting was selected then „X” input will be used for
connection of auger temperature sensor used for ignition detection.
A U G E R
I G N I T I O N
T E S T
Y E S
CAUTION!
In case emergency input is not used, „NO” parameter shall be selected
in „Auger ignition test” setting and contacts of „X” input shall be closed.
Auger ignition temperature
- this parameter specifies auger temperature, when the
controller activates auger ignition alarm. This parameter is unavailable when „NO”
was selected in „Auger ignition test” setting.
A U G E R
I G N I T I O N
T E M P E R A T U R E
8 0 c