![KEY RK-2006LSPz Operation Manual Download Page 17](http://html1.mh-extra.com/html/key/rk-2006lspz/rk-2006lspz_operation-manual_1960032017.webp)
17
Fan speed during cleaning mode
- only when AUTO is on.
F A N S P E E D D U R I N G
C L E A N I N G
1 0 0 %
Fan scavenge (air purging)
- the controller offers the function of scavenge (air
purging), which simply includes periodical switching on of the fan during burner
operation for the purpose of removal of accumulated gases.
F A N
S C A V E N G E
Y E S
Fan scavenge (air purging) blow time
- this parameter specifies blow time. This
setting is unavailable if „Fan scavenge” (air purging) setting was not selected.
F A N S C A V E N G E
B L O W T I M E
5 s
Fan scavenge (air purging) pause time
- this parameter specifies pause time
during scavenge. This setting is unavailable if „Fan scavenge” (air purging) setting
was not selected.
F A N S C A V E N G E
P A U S E
T I M E
1 m i n
Fan speed during scavenge (air purging)
- this parameter specifies fan power
during scavenge (air purging). This setting is unavailable if „Fan scavenge” (air
purging) setting was not selected.
F A N S P E E D D U R I N G
S C A V E N G E
1 0 0 %
5.3. Fuel auger operation parameters.
Auger filling time
- this parameter specifies time required for refilling the main
auger with fuel.
A U G E R F I L L I N G
T I M E
1 0 m i n
Initial fuel feed
- this parameter specifies time, when fuel will be fed before igniter
start. Selection of „0s” setting will switch off initial fuel dose feeding. In this case
„Fuel dose during ignition” setting shall be programmed as the value over „0%”.
I N I T I A L
F U E L
D O S E
1 0 s