F U E L
I G N I T I O N
T I M E
3 m i n
Ignition try count
- this parameter specifies how many times ignition may fail until
the controller activates „Out of fuel alarm” and switches into STOP mode. The alarm
is indicated with adequate message displayed on the display. To start the controller
first refill the fuel, then cancel by pressing STOP button and start setting mode by
pressing START button.
I G N I T I O N T R Y
C O U N T
2
Furnace extinction (shut down) time
- if the controller switches to extinction (shut
down) mode, the induction fan is activated according to power selected in „Fan
speed at extinction (shut down)” setting. After burner extinction (flame loss), the fan
operation follows according to time programmed in this setting. This function
ensures combustion of all fuel remains and burner cool down.
F U R N A C E
E X T I N C .
T I M E
5 m i n
Furnace cleaning mode
- this parameter specifies the way the cleaning mechanism
works.
-
„NONE"
- means that the burner does not have a cleaning mechanism. In
this case, the output DATA is working as an external alarm.
-
„CYCL."
- means the mode in which the cleaning procedure is run after the
firing and repeated at regular intervals until burner shut down is completed. Cleaning
procedure is attached to the time set in parameter „Cleaning mechanism work time".
After turning off the regulator, output deducts the time set in parameter „Cleaning
mechanism retraction time" and the time set in parameter „Cleaning mechanism
pause time".
-
„AUTO"
- means the cleaning procedure is started automatically after a
specified number shut downs or after a sufficient burner operation time. Automatic
cleaning means: burner shut down and start cleaning mechanism for the time set in
parameter „Cleaning mechanism work time". After turning off the regulator, output
deducts the time set in parameter "Cleaning mechanism retraction time" and then
goes to normal working cycle.
H E A R T H
C L E A N I N G
A U T O
Cleaning mechanism work time
- this parameter is available only when the
cleaning mechanism is activated (AUTO or CYCL. mode). It defines the time needed
to complete the full mechanism to open or move to end position.
M E C H A N I S M W O R K
T I M E
1 2 0 s