INSTALLATION. 

Install units in a 19 inch-wide rack. Optional slides may be used. Leave the front

and rear panels clear of obstructions to ensure adequate cooling. For parallel, series and master-slave
configurations, refer to the User Manual.

INPUT CONNECTIONS. 

 The user must provide a properly sized and rated mains lead (line cord) and

service with a current rating compatible with the anticipated input current (see Table 5 for mains voltage
range). Line cords and a user-wired source power connector are available as accessories (see Table 3).
Plug the source power connector into the source power inlet connector at the rear panel.

LOAD CONNECTIONS. 

Connect the load to the (+) and (–) DC OUTPUT terminals on the rear panel

(Figure 2). (+M) and (–M) outputs are for connection of error sense leads.

Configuration of local sensing is facilitated by pre-installed jumpers which configure the unit for local
sensing as shown in Figure 2.

NOTE: Output Sense lines must be connected for proper operation, either locally, or at the load

(remote). 

FIGURE 1.  KLP SERIES, FRONT PANEL CONTROLS AND INDICATORS

TABLE 5.  INPUT CURRENT SERVICE RATING AND CONDUCTOR SIZES

MAINS VOLTAGE RANGE

CURRENT SERVICE RATING

CONDUCTOR SIZE

90 - 132V a-c, 50/60Hz

20 Amp

#12AWG [2,0 mm²]

180 - 265V a-c, 50/60Hz

15 Amp

#14AWG [1,6 mm²]

Summary of Contents for KLP 10-150

Page 1: ...as a handy reference Refer to the KLP Developer s Guide for a full description of the digital interfaces their associated drivers and the SCPI command language Firmware Version Refer to www kepcopowe...

Page 2: ...he PRELIMINARY OPERATIONAL CHECK If any indication of damage is found file an imme diate claim with the responsible transport service EQUIPMENT SUPPLIED See Table 2 TABLE 1 MODEL PARAMETERS Model numb...

Page 3: ...2 0381 IEEE 488 GPIB Cable 1m long Connect KLP Power Supply to GPIB bus SNC 488 1 IEEE 488 GPIB Cable 2m long Connect KLP Power Supply to GPIB bus SNC 488 2 IEEE 488 GPIB Cable 4m long Connect KLP Pow...

Page 4: ...n error indication is blinking in the Status display refer to User Manual for an explanation of error codes 3 Rotate VOLTAGE adjust knob clockwise Verify that DC VOLTS display increases in large X 100...

Page 5: ...ords and a user wired source power connector are available as accessories see Table 3 Plug the source power connector into the source power inlet connector at the rear panel LOAD CONNECTIONS Connect t...

Page 6: ...S see Figure 2 FIGURE 2 KLP SERIES REAR PANEL VIEW JUMPERS INSTALLED FOR LOCAL SENSING REMOTE SENSING SELECT First remove the factory installed local sensing jumpers between S and M and between M and...

Page 7: ...e of the internal relay operation via the LAN interface or analog signals and setting coarse fine adjustment preference of the VOLTAGE and CURRENT controls An Installation Operation Summary is also in...

Page 8: ...how the actual output voltage and current Before enabling the output ALWAYS check the set points to avoid possible damage to the load 1 Tap either the VOLTAGE or CURRENT control The status display rea...

Page 9: ...s showing actual output current Similarly rotating the VOLTAGE control while in CC mode affects the voltage limit To change the limits to a precise value refer to SETPOINT ADJUSTMENT Voltage and curre...

Page 10: ...he output off flashes an overvoltage OVP or overcurrent OCP protection error message on the status display and sets a status bit that can be retrieved through the RS 232 GPIB or LAN port The unit must...

Page 11: ...13 228 1616 REV 7 11 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 1 O...

Page 12: ...28 1616 REV 7 070113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 2 O...

Reviews: