INSTALLATION.
Install units in a 19 inch-wide rack. Optional slides may be used. Leave the front
and rear panels clear of obstructions to ensure adequate cooling. For parallel, series and master-slave
configurations, refer to the User Manual.
INPUT CONNECTIONS.
The user must provide a properly sized and rated mains lead (line cord) and
service with a current rating compatible with the anticipated input current (see Table 5 for mains voltage
range). Line cords and a user-wired source power connector are available as accessories (see Table 3).
Plug the source power connector into the source power inlet connector at the rear panel.
LOAD CONNECTIONS.
Connect the load to the (+) and (–) DC OUTPUT terminals on the rear panel
(Figure 2). (+M) and (–M) outputs are for connection of error sense leads.
Configuration of local sensing is facilitated by pre-installed jumpers which configure the unit for local
sensing as shown in Figure 2.
NOTE: Output Sense lines must be connected for proper operation, either locally, or at the load
(remote).
FIGURE 1. KLP SERIES, FRONT PANEL CONTROLS AND INDICATORS
TABLE 5. INPUT CURRENT SERVICE RATING AND CONDUCTOR SIZES
MAINS VOLTAGE RANGE
CURRENT SERVICE RATING
CONDUCTOR SIZE
90 - 132V a-c, 50/60Hz
20 Amp
#12AWG [2,0 mm²]
180 - 265V a-c, 50/60Hz
15 Amp
#14AWG [1,6 mm²]