ACCESSORIES. 

See Table 3.

SAFETY. 

See Table 

4

TABLE 3.  ACCESSORIES

ITEM

FUNCTION

KEPCO

PART NUMBER

Line Cord Set (125V/20A)

2.5m long cord set, provides for source power 
connection. Mates with NEMA 5-20R receptacle 
(see adjacent figure). Supports rated load power 
over mains voltage range of 90-136V a-c.

NEMA 5-20R

118-0776

Line Cord Set (125V/15A)

2.5m long cord set, provides for source power 
connection. Mates with NEMA 5-15R receptacle 
(see adjacent figure). Supports restricted load 
power over mains voltage range of 90-136V a-c 
(contact Kepco Sales Engineering for details).

NEMA 5-15R

118-1136

Line Cord Set (250V/15A)

2.5m long cord set, provides for source power 
connection. Mates with NEMA 6-15R receptacle 
(see adjacent figure). Supports rated load power 
over mains voltage range of 180-265V a-c.

NEMA 6-15R

118-1137

Source power connector 

Mates with a-c input connector J1 (see Figure 1-2). Allows user to 
fabricate custom line cord.

142-0381

IEEE 488 (GPIB) Cable, 1m long

Connect KLP Power Supply to GPIB bus.

SNC 488-1

IEEE 488 (GPIB) Cable, 2m long

Connect KLP Power Supply to GPIB bus.

SNC 488-2

IEEE 488 (GPIB) Cable, 4m long

Connect KLP Power Supply to GPIB bus.

SNC 488-4

Chassis Slide

Allows rack-mounted units to slide in and out. Two (2) slides required 
per power supply.

108-0239 

(Jonathan 

375-QD Series)

Analog Connector Backshell

Locks analog port mating connector to KLP via jackscrews.

108-0204

Loop Back Test Connector

Used for verification of RS 232 operation.

195-0112

Null Modem Cable, 10 ft.

Connect RS 232 port with controlling computer, DB9F to DB9F, 10 feet 
long.

118-1176

Null Modem Cable, 1 ft.

Used for Master/Slave connections. Connects RS 232 ports of stacked 
power supplies, DB9F to DB9F, one foot long.

118-1220

LAN Patch cable

Connects KLP LAN port to LAN, 10 ft long.

118-1115

Support bracket, rear

Provides extra support to rear of rack-mounted unit if needed. Two 
brackets required per unit. Each bracket requires 2 screws and 2 
washers. See Figure 4, sheet 1, Detail “A” for requirements. 

128-2306

TABLE 4.  SAFETY SYMBOLS

SYMBOL

MEANING

CAUTION: RISK OF ELECTRIC SHOCK.

CAUTION: REFER TO REFERENCED PROCEDURE.

WARNING

INDICATES THE POSSIBILITY OF BODILY INJURY OR DEATH.

CAUTION

INDICATES THE POSSIBILITY OF EQUIPMENT DAMAGE.

!

Summary of Contents for KLP 10-150

Page 1: ...as a handy reference Refer to the KLP Developer s Guide for a full description of the digital interfaces their associated drivers and the SCPI command language Firmware Version Refer to www kepcopowe...

Page 2: ...he PRELIMINARY OPERATIONAL CHECK If any indication of damage is found file an imme diate claim with the responsible transport service EQUIPMENT SUPPLIED See Table 2 TABLE 1 MODEL PARAMETERS Model numb...

Page 3: ...2 0381 IEEE 488 GPIB Cable 1m long Connect KLP Power Supply to GPIB bus SNC 488 1 IEEE 488 GPIB Cable 2m long Connect KLP Power Supply to GPIB bus SNC 488 2 IEEE 488 GPIB Cable 4m long Connect KLP Pow...

Page 4: ...n error indication is blinking in the Status display refer to User Manual for an explanation of error codes 3 Rotate VOLTAGE adjust knob clockwise Verify that DC VOLTS display increases in large X 100...

Page 5: ...ords and a user wired source power connector are available as accessories see Table 3 Plug the source power connector into the source power inlet connector at the rear panel LOAD CONNECTIONS Connect t...

Page 6: ...S see Figure 2 FIGURE 2 KLP SERIES REAR PANEL VIEW JUMPERS INSTALLED FOR LOCAL SENSING REMOTE SENSING SELECT First remove the factory installed local sensing jumpers between S and M and between M and...

Page 7: ...e of the internal relay operation via the LAN interface or analog signals and setting coarse fine adjustment preference of the VOLTAGE and CURRENT controls An Installation Operation Summary is also in...

Page 8: ...how the actual output voltage and current Before enabling the output ALWAYS check the set points to avoid possible damage to the load 1 Tap either the VOLTAGE or CURRENT control The status display rea...

Page 9: ...s showing actual output current Similarly rotating the VOLTAGE control while in CC mode affects the voltage limit To change the limits to a precise value refer to SETPOINT ADJUSTMENT Voltage and curre...

Page 10: ...he output off flashes an overvoltage OVP or overcurrent OCP protection error message on the status display and sets a status bit that can be retrieved through the RS 232 GPIB or LAN port The unit must...

Page 11: ...13 228 1616 REV 7 11 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 1 O...

Page 12: ...28 1616 REV 7 070113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 2 O...

Reviews: