VFO SCAN
VFO Scan allows you to scan all frequencies from the
lowest frequency to the highest frequency on the band.
The current frequency step size {page 55} is used.
1
Select the desired band.
2
Press
[VFO] (1 s)
.
• The 1 MHz decimal blinks while scanning is in progress.
• Scan starts at the frequency currently displayed.
• To reverse the scan direction, turn the
Tuning
control
clockwise (upward scan) or counterclockwise
(downward scan), or press Mic
[UP]
/
[DWN]
.
3
To quit VFO Scan, press any key other than
[MHz]
and Mic
[UP]
/
[DWN]
.
Note:
The squelch must be closed for Scan to function.
MEMORY SCAN
Memory Scan allows all memory channels containing
data to be scanned.
1
Press
[MR] (1 s)
.
• The 1 MHz decimal blinks while scanning is in progress.
• Scan starts with the channel last recalled.
• To reverse the scan direction, turn the
Tuning
control
clockwise (upward scan) or counterclockwise
(downward scan), or press Mic
[UP]
/
[DWN]
.
2
To quit Memory Scan, press any key other than Mic
[UP]
/
[DWN]
.
Note:
◆
At least 2 or more memory channels must contain data and must not
be locked out.
◆
The squelch must be closed for Scan to function.
◆
The L1 to L6 and U1 to U6 memory channels and the priority channel
are not scanned.
◆
You can also start Memory Scan when in Channel Display mode.
While Scan is being interrupted, the channel number blinks.
◆
If you select “ONE” using Menu No. 4 (MR), memory channels on
only the current band will be scanned; otherwise, memory channels
on both VHF and UHF bands will be scanned.