PROGRAM SCAN
Program Scan is identical with VFO Scan except that
you select the frequency range of the scan.
■
Setting Scan Limits
You can store up to 6 scan ranges in memory
channels L1/U1 to L6/U6.
1
Select the desired band.
2
Select the desired frequency as the lower limit.
3
Press
[F]
.
4
Select a channel in the range from L1 to L6.
5
Press
[MR]
.
• The lower limit is stored in the channel.
6
Select the desired frequency as the upper limit.
7
Press
[F]
.
8
Select a matching channel in the range from U1 to
U6.
• If you have selected, for example, L3 in step 4,
select U3.
9
Press
[MR]
.
• The upper limit is stored in the channel.
10
To confirm the stored scan limits, press
[MR]
, then
select the L and U channels.
Note:
◆
The lower limit must be lower in frequency than the upper limit.
◆
The lower and upper frequency steps must be equal.
◆
The lower and upper limits must be selected on the same band.